Preview

INFLUENCE OF TOTAL HEAD OF FOAM ON OPTIMUM INTENSITY AND MINIMUM PARTICULAR EXPENSE SOLUTION SIZE OF FOAMER

https://doi.org/ 10.18322/PVB.2016.25.01.68-72

Abstract

The issues addressed included questions and prospects for use of the hydrocarbonic and fluorinated film-forming foamers for fire suppression of emergency passages and the fires of oil products in tanks at supply of foam from long distance. The results of the experiment show that hydrocarbonic foams with increase in falling height cause strong decrease in efficiency of fire suppression. The blow of foam about a surface conducts to partial immersions in oil product that leads to foam pollution by fuel. It is shown that using hydrocarbonic foamers with growth of total head from 5 to 15 cm a particular expense size and optimum intensity 2 times increase. While the fluorinated foams show increase inefficiency of fire suppression by increase in total head which is explained by superficial activity - aqueous solutions of film-forming foamers have positive value of spreading coefficient. The higher the drainage is, the stronger the foam and hydrocarbon surface hit that leads to the accelerated release of solution from foamy films more strongly and promotes fast foam spreading. Experiments confirm expert's opinion about low efficiency of the foams, received their hydrocarbonic foamers when giving with compact streams on long distance. Therefore replacing of fluorinated film-forming foamers with hydrocarbonic ones, which decay after application well, is premature.

About the Authors

A. . Kattge
Fire Department
Russian Federation


E. N. Degaev
Moscow State University of Civil Engineering
Russian Federation


References

1. Шароварников А. Ф., Воевода С. С., Молчанов В. П. Современные средства и способы тушения пожаров нефтепродуктов. - М. : Калан, 2000. - 420 с.

2. Корольченко Д. А., Шароварников А. Ф., Дегаев Е. Н. Лабораторная методика определения изолирующих свойств пены на поверхности гептана // Пожаровзрывобезопасность. - 2014. - Т. 23, № 4. - С. 72-76.

3. Шароварников А. Ф., Корольченко Д. А. Тушение горючих жидкостей распыленной водой // Пожаровзрывобезопасность. - 2013. - Т. 22, № 11. - С. 70-74.

4. Шароварников А. Ф., Корольченко Д. А. Влияние дисперсности капель воды на эффективность тушения пожаров горючей жидкости // Пожаровзрывобезопасность. - 2013. -Т. 22, № 12. - С. 69-74.

5. Sharovarnikov A. F., Punchik G. I. Experimental determination of the strength of foams with high foam densities // Colloid Journal. - 1982. - Vol. 44, No. 1. - P. 180-182.

6. Bikerman J. J. Foams. -New York : Springer, 1973. DOI: 10.1007/978-3-642-86734-7.

7. Oil Tank Fire Extinguishing // Fire. - October, 1960. - No. 109. - P. 1-43.

8. Jho C. Spreading of aqueous solutions of a mixture of fluoro- and hydrocarbon surfactants on liquid hydrocarbon substrates // Journal of Colloid and Interface Science. - 1987. - Vol. 117, No. 1. - P. 139-148. DOI: 10.1016/0021-9797(87)90176-7.

9. Борковская B. Г., Агапов C. В. Стандарты и требования пожарной безопасности // Пожаровзрывобезопасность. - 2014. - Т. 23, № 11. - С. 7-14.

10. Борковская В. Г. Новые требования профессиональных рисков в пожарной безопасности // Пожаровзрывобезопасность. - 2013. - Т. 22, № 12. - С. 9-15.

11. Корольченко Д. А., Дегаев Е. Н., Шароварников А. Ф. Горение гептана в модельном резервуаре // Пожаровзрывобезопасность. - 2015. - Т. 24, № 2. - С. 67-70.

12. Корольченко Д. А., Шароварников А. Ф., Дегаев Е. Н. Классификация пенообразователей для тушения пожаров нефтепродуктов по структуре коэффициента растекания рабочего раствора по углеводороду // Пожаровзрывобезопасность. - 2015. - Т. 24, № 8. - С. 75-80. DOI: 10.18322/PVB.2015.24.08.75-80.


Review

For citations:


Kattge A., Degaev E.N. INFLUENCE OF TOTAL HEAD OF FOAM ON OPTIMUM INTENSITY AND MINIMUM PARTICULAR EXPENSE SOLUTION SIZE OF FOAMER. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2016;25(1):68-72. (In Russ.) https://doi.org/ 10.18322/PVB.2016.25.01.68-72

Views: 435


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 0869-7493 (Print)
ISSN 2587-6201 (Online)