Preview

Advantages of the fire extinguishing systems carbon dioxide with the elimination of burning tanks with petroleum products

https://doi.org/10.18322/PVB.2016.25.12.69-75

Abstract

Introduction. At the moment for extinguishing oil and petroleum products in vertical steel tanks widely used air-mechanical foam. The main reason for its poor performance is the inability to isolate the source of fire on the environment. This red-hot tank walls are a good source to ignite heated vapors of a flammable liquid that spread quickly through the crumbling foam layer. The use of carbon dioxide to extinguish a vertical steel tanks is a new, highly effective. The main prevailing differences of this installation are the response time and integrated quenching method - simultaneous exclusion oxidizer and an ignition source (hot tank walls). Supplying foam solution tank time is approximately 5 minutes after the operation of the ignition signal, and carbon dioxide fills the interior of the tank in 30 seconds. Description of experimental studies. The efficiency of the installation of gas fire extinguishing based on isothermal with carbon dioxide module is confirmed by field trials. Tests were conducted on a model of the vertical tank RVS-1000 10 m in diameter. The mixture was used as fuel oil (99 % by weight of oil) and gasoline (up to 1 % by weight). Estimated number of gas extinguishing agent is 1021 kg. Tests were carried out in three stages: the main issue of the calculated amount of extinguishing agent; release of a reserve stock of the fire extinguishing agent 15 minutes after the second planned arson former oil composition; the use of stock to cope with the extinguishing agent after the smuggled from mobile isothermal containers while maximizing the free burning time. Results and conclusions. Permanent installation of gas fire extinguishing module based on isothermal with carbon dioxide has proven effective for fire suppression vertical steel tanks with oil and oil products. Fire suppression time is less than 60 seconds. Upper accommodation efficiency of the distribution manifold as compared to the lower placing is confirmed. Besides, simultaneously with fire extinguishing it’s occurred efficient cooling of tank walls that previously could not be achieved by other systems. A significant result of the experiment is also a high performance fire-fighting technology using additional reserve amount of extinguishing agent after the first start-up and the ability to recharge from the mobile isothermal containers.

About the Authors

A. D. Groshev
Воронежский государственный технический университет
Russian Federation


I. I. Pereslavtseva
Воронежский государственный технический университет
Russian Federation


References

1. Пузач С. В., Колодяжный С. А., Колосова Н. В. Модифицированная зонная модель расчета термогазодинамики пожара в помещении, учитывающая форму конвективной колонки // Пожаровзрывобезопасность.- 2015.-Т. 24,№ 12.-С. 33-39. DOI: 10.18322/PVB.2015.24.12.33-39.

2. Колодяжный С. А., Переславцева И. И. Математическое моделирование динамики основных опасных факторов в начальной стадии пожара // Известия Казанского государственного архитектурно- строительного университета. -2014. -№ 4. -С. 403-412.

3. Меркулов А. В., Меркулов В. А. Установки газового пожаротушения // Пожаровзрывобезопасность. -2002.-Т. 11, № 6. -С. 75-78.

4. Creitz E. C. Inhibition of diffusion flames by methyl bromide and trifluoromethyl bromide applied to fuel and oxygen sides of the reaction zone//Journal of Research of the National Bureau of Standards. Section A: Physics and Chemistry. -1961.-Vol. 65A, No. 4. -P. 389-396. DOI: 10.6028/jres.065a.039.

5. Burke R., van Tiggelen A. Kinetics of laminar premixed methane-oxygen-nitrogen flames // Bulletin des Sociйtйs Chimiques Belges. - 1965. - Vol. 74, No. 9-10. - P. 426-449. DOI: 10.1002/bscb.19650740907.

6. Бабуров В. П., Бабурин В. В., Фомин В. И., Смирнов В. И. Производственная и пожарная автоматика. Ч. 2. Автоматические установки пожаротушения. - М. : Академия ГПС МЧС России, 2007. -298 с.

7. Старков Н. Н. Тушение пожаров нефтепродуктов и полярных жидкостей диоксидом углерода твердым гранулированным : дис. …канд. техн. наук. -М., 2009. -191 с.

8. Шарапов С. В., Боблак В. А. Экспериментальные исследования по применению жидкой двуокиси углерода для тушения пожаров в резервуарных парках хранения нефти и нефтепродуктов // Вестник Санкт-Петербургского университета Государственной противопожарной службыМЧСРоссии. -2012. -№ 2. -С. 52-57.

9. Шарапов С. В., Боблак В. А. Применение жидкой двуокиси углерода для тушения пожаров в резервуарных парках хранения нефти и нефтепродуктов // Проблемы управления рисками в техносфере. -2012.-Т. 22, № 2. -С. 60-67.

10. Меркулов В. А., Кузьменко К. П., Глухов В. И. Ретроспектива одной из инноваций // Территория Нефтегаз. -2016.-№ 2. -С. 16-17.

11. Меркулов В. А., Кузьменко К. П., Кирсанов А. И. Тушение диоксидом углерода пожаров в вертикальных стальных резервуарах с нефтью и нефтепродуктами // Пожаровзрывобезопасность.- 2013. -Т. 22, № 3. -С. 58-61.

12. Кирсанов А. И. Противопожарная защита резервуарных парков для хранения нефтепродуктов // Актуальные проблемы пожарной безопасности : Материалы XXV Междунар. науч.-практ. конф. -М. : ВНИИПО, 2013.-С. 464-472.

13. Кирсанов А. И., Сонечкин В. М., Алешков А. М. Определение оптимальной конструкции устройства подачи двуокиси углерода при тушении стальных резервуаров с нефтью и нефтепродуктами // Актуальные проблемы пожарной безопасности : Материалы XXVII Междунар. науч.-практ. конф. -М. : ВНИИПО, 2015.-С. 45-56.

14. Murphy R. F. Guidelines optimize foam fire fighting system // Oil and Gas Journal.-1982.-No. 4. -P. 229-232.

15. СП 155.13130.2014. Cклады нефти и нефтепродуктов. Требования пожарной безопасности. - Введ. 01.01.2014.-М. : МЧС России, 2014.


Review

For citations:


Groshev A.D., Pereslavtseva I.I. Advantages of the fire extinguishing systems carbon dioxide with the elimination of burning tanks with petroleum products. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2016;25(12):69-75. (In Russ.) https://doi.org/10.18322/PVB.2016.25.12.69-75

Views: 521


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 0869-7493 (Print)
ISSN 2587-6201 (Online)