Preview

Pozharovzryvobezopasnost/Fire and Explosion Safety

Advanced search

Study of statistics fire equipment for fire extinguishing

https://doi.org/10.18322/PVB.2016.25.06.48-54.

Abstract

The article raises a topical issue - the issue of improving extinguishing oil fires and oil in tank farms, despite the progress made in fire safety for oil and petroleum products storage tanks are one of the most dangerous objects. According to statistical data the majority of fires at these facilities is quenched by means of a mobile fire fighting equipment, and the main fire extinguishing agent is air-mechanical foam of low and medium ratio, extinguishing properties are well understood and known. The world’s leading manufacturers are constantly working to develop and search for fire extin-guishing substances, methods and means of their delivery in fires on oil products storage and processing facilities. Not so long ago, in our country there is a new type of foam based on structured silica particles “solid foam” becomes relevant question is a comprehensive study of the effectiveness of extin¬guishing agents, methods and ways of delivering the fire and feed it to put out fires of oil and petro¬leum products. In the course of analyzing the use of the intended use, the frequency of use of foam extinguishing vehicles in the past 10 years cars is 25 % of the use of the intended use of vehicles, in this case against the background of reducing the number of fires found that these cars are still in demand and frequency of their use does not decrease much. In addition, the analysis of regulations governing the classification and the main types of fire intended use of vehicles leads to the conclusion about the absence of foam extinguishing vehicles in container design and chassis trailers. All this allows us to state a fact necessary to create and implement, new foam extinguishing car models with the use of foam on the basis of structured silica particles, what will increase the fire safety of oil and gas facilities, the effectiveness of actions of fire-rescue units to extinguish fires by im¬proving the cha-racteristics of the extinguishing agent.

About the Authors

А. Калач
Воронежский институт ГПС МЧС России
Russian Federation


С. Шарапов
Санкт-Петербургский университет ГПС МЧС России
Russian Federation


А. Гусаков
Воронежский институт ГПС МЧС России
Russian Federation


References

1. Руководство по тушению нефти и нефтепродуктов в резервуарах и резервуарных парках.-М. : ГУ ГПС - ВНИИПО - МИПБ, 1999. -47 c.

2. Шароварников А. Ф., Молчанов В. П., Воевода С. С., Шароварников С. А. Тушение пожаров нефти и нефтепродуктов -М. : Изд. дом “Калан”, 2002. -448 с.

3. Бастриков Д. Л. Комбинированный способ тушения пожаров автомобильных бензинов европейского стандарта в наземных вертикальных стальных резервуарах : автореф. дис. … канд. техн. наук. -М., 2013.-23 с.

4. Tafreshi A. M., Di Marzo M. Foams and gels as fire protection agents // Fire Safety Journal. - November 1999.-Vol. 33, Issue 4.-P. 295-305. DOI: 10.1016/s0379-7112(99)00031-4.

5. Шароварников А. Ф., Шароварников С. А. Пенообразователи и пены для тушения пожаров. Состав, свойства, применение. -М. : Пожнаука, 2005. -335 с.

6. Magrabi S. A., Dlugogorski B. Z., Jameson G. J. A comparative study of drainage characteristics in AFFF and FFFP compressed-air fire-fighting foams // Fire Safety Journal. - February 2002. - Vol. 37, Issue 1. -P. 21-52. DOI: 10.1016/s0379-7112(01)00024-8.

7. Lattimer B. Y., Trelles J. Foam spread over a liquid pool // Fire Safety Journal.-June 2007.-Vol. 42, Issue 4. -P. 249-264. DOI: 10.1016/j.firesaf.2006.10.004.

8. Lattimer B. Y., Hanauska Ch. P., Scheffey J. L., Williams F. W. The use of small-scale test data to characterize some aspects of fire fighting foam for suppression modeling // Fire Safety Journal. - March 2003. -Vol. 38, Issue 2. -P. 117-146. DOI: 10.1016/s0379-7112(02)00054-1.

9. Кокорин В. В., Романова И. Н., Хафизов Ф. Ш. Проблемы эффективного тушения пожаров вертикальных стальных резервуаров в слой горючего // Нефтегазовое дело : электронный научный журнал. - 2012. - № 3. - C. 255-260. URL: http://ogbus.ru/authors/Kokorin/Kokorin/1.pdf (дата обращения: 20.02.2016).

10. Официальный сайтООО“НПОСОПОТ”.URL: http://www.sopot.ru (дата обращения: 10.02.2016).

11. Твердая пена против огня : интервью с Александром Виноградовым. URL: http://rusplt.ru/sdelano-russkimi/tverdaya-pena-protiv-ognya-17905.html (дата обращения: 10.02.2016).

12. Типаж пожарных автомобилей на 2011-2015 гг.-М. :ФГУВНИИПОМЧСРоссии, 2011.-71 с.

13. Пожары и пожарная безопасность : статистические сборники за 2005-2014 гг.-М. : ВНИИПО МЧС России, 2005-2014


Review

For citations:


 ,  ,   Study of statistics fire equipment for fire extinguishing. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2016;25(6):48-54. (In Russ.) https://doi.org/10.18322/PVB.2016.25.06.48-54.

Views: 649


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 0869-7493 (Print)