Extinguishing a fire on a vent stack using a gas-powder fire extinguishing composition
https://doi.org/10.22227/0869-7493.2026.35.02.5-11
Abstract
Introduction. Vent stacks are used for the safe release of liquefied natural gas (LNG) vapors from safety valves. Unlike flare stacks, they are not designed for gas combustion; however, there is a risk of their ignition from external sources, such as lightning strikes or static electricity. Prompt extinguishing of such a fire helps prevent prolonged thermal impact on the structures.
Research Methodology. At the test site, a gas-powder fire extinguishing module was connected to the base of a vent stack mock-up. After igniting the LNG vapors at the head of vent stack and stabilizing the flame, the fire extinguishing module was manually activated. The extinguishing result was recorded visually.
Results. It was established that supplying a gas-powder fire extinguishing composition (GPFEC) into the pipe interior of the vent stack leads to the extinguishing of the fire at the head. Complete extinguishing was achieved with a GPFEC flow rate of at least 1.8 kg/s. Based on the obtained data, parameters for designing gas-powder fire extinguishing systems were determined. The consumption of the fire extinguishing agent must be at least 311 kg/m2, and the supply intensity at least 102 kg/(m2∙s), calculated based on the cross-sectional area of the vent stack.
Conclusions. The proposed method of supplying the GPFEC into the pipe interior is an effective way to extinguish a fire on a vent stack. The obtained experimental values of the extinguishing composition flow rate and supply intensity can be used to calculate the parameters of gas-powder fire extinguishing systems when protecting vent stack.
Keywords
About the Authors
A. B. SaenkovaRussian Federation
Alexandra B. SAENKOVA, Chief Designer
Skobyanoe Highway, 3, Moscow Region, Sergiev Posad, 141300
RSCI AuthorID: 1108799, ResearcherID: IUP-7179-2023
V. I. Seliverstov
Russian Federation
Vladimir I. SELIVERSTOV, Cand. Sci. (Eng.), General Director
Skobyanoe Highway, 3, Moscow Region, Sergiev Posad, 141300
RSCI AuthorID: 975258; ResearcherID: IUP-8784-2023
D. A. Korolchenko
Russian Federation
Dmitriy A. KOROLCHENKO, Dr. Sci. (Eng.), Professor, Head of Institute of Complex Safety in Construction
Yaroslavskoe Shosse, 26, Moscow, 129337
RSCI AuthorID: 352067; Scopus AuthorID: 55946060600; ResearcherID: E-1862-2017
References
1. Voevoda S.S., Gordienko D.M., Shebeko Yu.N., Shebeko A.Yu., Lagozin A.Yu., Mordvinova A.V. Foreign experience of dry powder fire extinguishing systems for installation with flammable gases. Fire Safety. 2015; 4:130-142. EDN VCMKAJ. (rus).
2. Saenkova A.B. Foreign experience in the use of powder fire extinguishing systems for the protection of facilities for the circulation of liquefied natural gas. Current Issues of Fire Safety : Proceedings of the XXXV International Scientific and Practical Conference. Moscow, All-Russian Order of the Badge of Honour Research Institute for Fire Defense of the Ministry of the Russian Federation for Civil Defence, Emergencies and Elimination of Consequences of Natural Disasters, 2023; 239-243. (rus).
3. Chuguev A.P., Mordvinova A.V., Sychev A.N., Fedorinov M.V. Analytical review of fire safety equipment for operations with liquefied combustible gases. Current Fire Safety Issues. 2020; 3(5). DOI: 0.37657/vniipo.avpb.2020.93.56.003. EDN IMTPIU. (rus).
4. Suardin J.A., Wang Y., Willson M., Mannan M.S. Field experiments on high expansion (HEX) foam application for controlling LNG pool fire. Journal of hazardous materials. 2009; 165(1-3):612-622. DOI: 10.1016/j.jhazmat.2008.10.040. EDN KPQICN.
5. Zhang Z., Krishnan P., Jiao Z., Mannan M.S., Wang Q. Developing a CFD heat transfer model for applying high expansion foam in an LNG spill. Journal of Loss Prevention in the Process Industries. 2021; 71:104456. DOI: 10.1016/j.jlp.2021.104456. EDN MIPREL.
6. Guo X., Ye C., Liang X., Pan X., Hua M., Cyril G.S. et al. Analysis on the effects of high expansion foam on evaporation rate of the LNG. Safety Science. 2021; 137:105183. DOI: 10.1016/j.ssci.2021.105183. EDN AHEMQV.
7. Takeno K., Ichinose T., Tokuda K., Ohba R., Yoshida K., Ogura K. Effects of high expansion foam dispersed onto leaked LNG on the atmospheric diffusion of vaporized gas. Journal of Loss Prevention in the Process Industries. 1996; 9(2):125-133. DOI: 10.1016/0950-4230(95)00062-3
8. Aleshkov M.V., Molchanov V.P., Makarov S.A., Ioshchenko D.A., Bituev R.B., Tretyakov A.V. Determining critical foam layer thickness for localization and elimination of liquefied natural gas spills flame combustion. Fire and emergencies: prevention, elimination. 2023; 3:5-14. DOI: 10.25257/FE.2023.3.5-14. EDN SNDCZV. (rus).
9. Bezborodov V.I., Baklykov V.N., Makarova T.P., Fomenko A.V., Baturo A.N. Assessment of fire extinguishing performance of various foam types for liquefied natural gas suppression. Fire and emergencies: prevention, elimination. 2025; 4:61-71. DOI: 10.25257/FE.2025.4.61-71. EDN SNDCZV. (rus).
10. Hu W., Yu R., Chang Z., Tan Z., Liu X. The fire extinguishing mechanism of ultrafine composite dry powder agent containing Mg(OH)2. International Journal of Quantum Chemistry. 2021; 121(24):e26810. DOI: 10.1002/qua.26810. EDN CWRTJT.
11. Baratov A.N., Molchadsky I.S. Combustion during a fire. Moscow, VNIIPO EMERCOM of Russia, 2011; 502. EDN QNPPKF. (rus).
12. Krasnyansky M.E. Fire-extinguishing and explosion-suppressing powders. Donetsk, Donbas, 1990; 110. URL: https://mchs.fun/ognetushashhie-i-vzryvopodavlyayushhie-poroshki-krasnyanskij-m-e-doneczk-donbas-1990 (rus).
13. Saenkova A., Seliverstov V., Bezborodov V., Brytkov S., Korolchenko D. Extinguishing the LNG jet fire with gas-powder fire extinguishing installations. E3S Web of Conferences. 2024; 533:02046. DOI: 10.1051/e3sconf/202453302046. EDN HBHIZT.
14. Seliverstov V.I., Saenkova A.B. The concept of fire protection for small-scale LNG production and consumption facilities. PRONEFT. Professionals about oil. 2023; 8(1):123-128. DOI: 10.51890/2587-7399-2023-8-1-123-128. EDN DHVUCU. (rus).
15. Le G.H., Thanh D.A., My P.T., Pham T.T., Quan T.T., Nguyen Q.M. et al. Synthesis of magnesium hydroxide powder and dry powders for application in extinguishing petroleum fires. Vietnam Journal of Chemistry. 2024; 62(S1):68-75. DOI: 10.1002/vjch.202300279. EDN UHSOQE.
16. Lu G., Zhao Ju., Zhou Ya., Fu Ya., Lu S., Zhang H. Study on flowability enhancement and performance testing of ultrafine dry powder fire extinguishing agents based on application requirements. Fire. 2024; 7(4):146. DOI: 10.3390/fire7040146. EDN VTLJBP.
17. Liu H., Zhang T., Zhang C., Xiao L., Liang Q. Application of a novel a core-shell microstructured nanocomposites as a fire extinguishant using seawater. E3S Web of Conferences. EDP Sciences, 2021; 237:01009. DOI: 10.1051/e3sconf/202123701009. EDN VOPRXO.
18. Wang L., Du Sh., Zhou Zh., Guo Y., Yang Qi., Yao S. et al. Enhanced Fire-Extinguishing Performance and Synergy Mechanism of HM/DAP Composite Dry Powder. Materials. 2025; 18(3):533. DOI: 10.3390/ma18030533. EDN YBTTRO.
19. Heymes F., Hoorelbeke P., Roosendans D., Dutertre A., Helschger G. An Experimental Investigation on Fire Extinguishing Powder Efficiency. Chemical Engineering Transaction. 2020; 82:241-246. DOI: 10.3303/CET2082041
20. Guo X., Pan X., Zhang L., Hua M., Li H., Li S. et al. The inhibitory combustion reaction performance and tail gas analysis of composite ultra-fine dry powder extinguishing agent containing different additives. Journal of Loss Prevention in the Process Industries. 2020; 65:104153. DOI: 10.1016/j.jlp.2020.104153. EDN SZBLQB.
Review
For citations:
Saenkova A.B., Seliverstov V.I., Korolchenko D.A. Extinguishing a fire on a vent stack using a gas-powder fire extinguishing composition. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2026;35(2):5-11. (In Russ.) https://doi.org/10.22227/0869-7493.2026.35.02.5-11
JATS XML






















