Preview

Pozharovzryvobezopasnost/Fire and Explosion Safety

Advanced search

Fire resistance of building structures made of rolled steel with increased heat resistance indicators

https://doi.org/10.22227/0869-7493.2024.33.03.47-56

Abstract

Introduction. The paper is devoted to experimental and analytical study of the load-bearing capacity of bending structures made of ordinary and fire-resistant rolled steel under standard temperature conditions. Fire tests were carried out with rolled I-beams No. 20B1 manufactured according to GOST R 57837–2017 from steels of strength classes C255, C390 and welded I-beams 180 × 90 × 10 from steels C355, C390, C355P, C390P with the length of 3,500 mm. Experiments on determination of high-temperature mechanical properties of new steel grades were carried out.

Materials and methods. The values of actual fire resistance limits of beams obtained experimentally are determined according to GOST 30247.1–94 and GOST 30247.0–94. The thermotechnical part of the calculation of the temperature in the cross-section of steel beams was performed in the ANSYS Mechanical programme complex. The calculation of bearing capacity was carried out according to the developed method and the registered programme for computer. Experiments on determination of mechanical properties of rolled metal products under high-temperature heating were carried out on small-sized specimens in accordance with GOST 9651–84.

Results and discussion. Experimentally obtained values of actual fire resistance limits for I-beams made of ordinary and fire-resistant rolled steel. The averaged values of coefficients of change of yield strength at elevated temperatures of construction rolled steel, including fire-resistant steel, which can be used in calculation models of fire resistance assessment of steel structures, were determined. A programme complex for calculation of fire resistance limit taking into account non-uniform temperature distribution in the cross-section of the structure was developed. The results of calculations of fire resistance limits according to the proposed model are close to the experimental data obtained on I-beams made of building steels, including fire-resistant ones.

Conclusions. The fire resistance limit of beams made of fire-resistant rolled steel C355P, C390P at standard temperature regime occurs 10–15 minutes later than beams made of ordinary construction steel. The results of experimental and analytical studies of fire resistance limits of structures made of new types of fire-resistant steels confirm the increase in the time of metal heating from the beginning of fire exposure to the achievement of critical temperature in the design cross-section, which allows to justify their use in the design of buildings and structures in accordance with the requirements of standardized documents on fire safety, as well as to reduce the use of fireproof materials, reduce the metal intensity and cost of construction.

About the Authors

V. I. Golovanov
All-Russian Research Institute for Fire Protection of Ministry of Russian Federation for Civil Defense, Emergencies and Elimination of Consequences of Natural Disasters
Russian Federation

Vladimir I. GOLOVANOV, Dr. Sci. (Eng.), Chief Researcher

VNIIPO, 12, Bala­shikha, Moscow Region, 143903



A. V. Pekhotikov
All-Russian Research Institute for Fire Protection of Ministry of Russian Federation for Civil Defense, Emergencies and Elimination of Consequences of Natural Disasters
Russian Federation

Andrey V. PEKHOTIKOV, Cand. Sci. (Eng.), Head of Department

VNIIPO, 12, Balashikha, Moscow Region, 143903



D. N. Pristupyuk
The State Fire Academy of the Ministry of Russian Federation for Civil Defense, Emergencies and Elimination on Consequences of Natural Disasters
Russian Federation

Dmitriy N. PRISTUPYUK, Cand. Sci. (Eng.), Head of the Fire Safety in Construction Department

Borisa Galushkina St., 4, Moscow, 129366



G. I. Kryuchkov
The State Fire Academy of the Ministry of Russian Federation for Civil Defense, Emergencies and Elimination on Consequences of Natural Disasters
Russian Federation

Gennadiy I. KRYUCHKOV, Senior Software Engineer of Educational and Scientific Complex of Fire Safety Protection Facilities

Borisa Galushkina St., 4, Moscow, 129366

ResearcherID: ACV-2350-2022



References

1. Golovanov V.I., Pronin D.G. Influence of the development of the normative base in the field of fire resistance on the use of steel in construction. Industrial and Civil Engineering. 2021; 10:14-29. (rus).

2. Odessky P.D., Vedyakov I.I. Steel in building metal structures. Moscow, Metallurgizdat Publ., 2018; 906. (rus).

3. Fedorov V.S., Levitskiy V.E., Molchadskiy I.S., Aleksandrov A.V. Fire behavior and fire danger of building designs. Moscow, ASV Publ., 2009; 408. (rus).

4. Golovanov V.I., Pekhotikov A.V., Kryuchkov G.I., Novikov N.S. Fire resistance of steel building beams. Fire safety. 2022; 4(109):19-28. DOI: 10.37657/vniipo.pb.2022.109.4.001 (rus).

5. Golovanov V.I., Pekhotikov A.V., Kryuchkov G.I., Pavlov V.V., Novikov N.S. Features of сalculating the fire resistance limit of beams from construction steels. Occupational Safety in Industry. 2023; 3:7-13. DOI: 10.24000/0409-2961-2023-­3-7-13 (rus).

6. Korolchenko D.A., Eremina T.Yu., Puzach S.V., Portnov F.A. Simulation of nomograms showing the heating of steel structures with flame retardant coatings of different thicknesses (in the water). Pozharovzryvobezopasnost/Fire and Explosion Safety. 2022; 31(6):30-46. DOI: 10.22227/0869-7493.2022.31.06.30-46 (rus).

7. Golovanov V.I., Kryuchkov G.I., Strekalev A.N., Komissarov A.A., Tikhonov S.M. A study on mechanical properties of modern rolled structural metal at elevated temperatures. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2022; 31(2):52-62. DOI: 10.22227/0869-7493.2022.31.02.52-62 (rus).

8. Odessky P.D., Kulik D.V. Steels with high resistance to extreme impacts. Moscow, Intermet Engineering Publ., 2008; 239. (rus).

9. Shi Y., Wang J., Zhou X., Xue X., Li Y. Post-fire mechanical properties of Q960 cold-formed thick-walled ultra-high-strength steel. Fire Technology. 2024; 60:1917-1953. DOI: 10.1007/s10694-024-01555-3

10. Su A., Wang Yа., Wang Yu., Rasmussen K.J.R., Gardner L. Behaviour and design of S960 ultra-high strength steel non-slender welded I-section beam–columns. Engineering Structures. 2024; 304:117602. DOI: 10.1016/j.engstruct.2024.117602

11. Komissarov A.A., Tikhonov S.M., Ten D.V., Matrosov M.Yu., Glukhov P.A. Comparative fire resistance of modern construction steels. Steel in Translation. 2021; 51(11):827-833. DOI: 10.3103/S0967091221110073

12. Lennon T., Mur D.B., Vang Yu.K., Beyli K.G. Guide for designers to EN 1991-1-2, 1992-1-2, 1993-1-2 and 1994-1-2 : handbook for the design of fire protection of steel, steel-reinforced concrete and concrete structures of buildings and structures in accordance with Eurocodes. Moscow, MGSU, 2013; 195. (rus).

13. Botyan С.С., Zhamoydik С.М., Olesiyuk Н.М. Analysis of evaluation methods of fire resistance of steel building structures, taking into account the effect of heat transfer with adjacent structures. Journal of Civil Protection. 2023; 7(2):­­131-143. DOI: 10.33408/2519-237X.2023.7-2.131 (rus).

14. Yakovlev A.I. Calculation of fire resistance of building structures. Мoscow, Stroyizdat Publ., 1988; 143. (rus).

15. Komissarov A.A., Tikhonov S.M., Ten D.V., Matrosov M.Yu., Shulga E.V. Fire resistance factors of low-alloyed construction longs. Steel in Translation. 2022; 52(7):701-706. DOI: 10.3103/S0967091222070099

16. Komissarov A.A., Tikhonov S.M., Ten D.V., Mazova E.P., Matrosov M.Yu., Glukhov P.A. et al. Analysis of the use of fire-resistant rolled steel S390P for the manufacture of building steel structures. Steel. 2022; 12:54-58. (rus).

17. Wang W.Y., Zhang L., He P. A numerical investigation on restrained high strength Q460 steel beams including creep effect. International Journal of Steel Structures. 2018; 18(1):1497-1507. DOI: 10.1007/s13296-018-0047-9

18. Dwaikat M.M.S., Kodur V.R. A performance based methodology for fire design of restrained steel beams. Journal of Constructional Steel Research. 2011; 67(3):510-524. DOI: 10.1016/j.jcsr.2010.09.004

19. Łukomski M., Turkowski P., Roszkowski P., Bartłomiej P. Fire resistance of unprotected steel beams — comparison between fire tests and calculation models. Procedia Engineering. 2017; 172:665-672. DOI: 10.1016/j.proeng.2017.02.078

20. Ghafouri M., Afkhami S., Pokka A.-P., Javaheri V., Togiani A., Larkiola J. et al. Effect of temperature on the plastic flow and strain hardening of direct-quenched ultra-high strength steel S960MC. Thin-Walled Structures. 2024; 194:111319. DOI: 10.1016/j.tws.2023.111319


Review

For citations:


Golovanov V.I., Pekhotikov A.V., Pristupyuk D.N., Kryuchkov G.I. Fire resistance of building structures made of rolled steel with increased heat resistance indicators. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2024;33(3):47-56. (In Russ.) https://doi.org/10.22227/0869-7493.2024.33.03.47-56