<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">firesmi-762</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ВОПРОС - ОТВЕТ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>QUESTION - ANSWER</subject></subj-group></article-categories><title-group><article-title>Частные вопросы по проектированию внутреннего противопожарного водопровода</article-title><trans-title-group xml:lang="en"><trans-title>Special issues on design installation of standpipe and hose systems</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мешман</surname><given-names>Л. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Meshman</surname><given-names>L. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>МЕШМАН Леонид Мунеевич, кандидат технических наук, старший научный сотрудник, ведущий научный сотрудник</p><p>143903, г. Балашиха Московской обл., мкр. ВНИИПО, 12</p></bio><bio xml:lang="en"/><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Всероссийский научно-исследовательский институт противопожарной обороны МЧС России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>All-Russian Research Institute for Fire Protection of Emercom of Russia</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2019</year></pub-date><pub-date pub-type="epub"><day>03</day><month>07</month><year>2019</year></pub-date><volume>28</volume><issue>3</issue><fpage>98</fpage><lpage>100</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Мешман Л.М., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Мешман Л.М.</copyright-holder><copyright-holder xml:lang="en">Meshman L.M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/762">https://www.fire-smi.ru/jour/article/view/762</self-uri><abstract><p>Рекомендовано количество пожарных кранов, одновременно используемых при тушении пожара, а также минимальный расход воды на пожаротушение определять согласно таблице, в которой представлены все виды зданий, сооружений и помещений в соответствии с их функциональным назначением (Ф1-Ф4). </p></abstract><trans-abstract xml:lang="en"><p>It is recommended to determine the number of fire hydrants (FG) simultaneously used in the fire extinguishing, as well as the minimum water consumption for firefighting according to the table, which presents all types of buildings, structures and premises in accordance with their functional purpose according to F1-F4.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>виды зданий</kwd><kwd>сооружений и помещений</kwd><kwd>функциональное назначение</kwd><kwd>пожарный кран</kwd><kwd>пожаротушение</kwd><kwd>минимальный расход воды</kwd><kwd>высота помещения</kwd></kwd-group><kwd-group xml:lang="en"><kwd>types of buildings</kwd><kwd>structures and premises</kwd><kwd>functional purpose</kwd><kwd>fire hydrants</kwd><kwd>fire extinguishing</kwd><kwd>minimum water consumption</kwd><kwd>room height</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
