<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">firesmi-750</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ВОПРОС - ОТВЕТ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>QUESTION - ANSWER</subject></subj-group></article-categories><title-group><article-title>Влияние проектного значения интенсивности орошения диктующего оросителя на гидравлические параметры распределительной сети АУП</article-title><trans-title-group xml:lang="en"><trans-title>Effect of irrigation intensity design value dictating the sprinkler on the hydraulic parameters of the distribution network AFES</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мешман</surname><given-names>Л. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Meshman</surname><given-names>Leonid M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>143903, г. Балашиха Московской обл., мкр. ВНИИПО, 12</p><p>МЕШМАН Леонид Мунеевич, канд. техн. наук, ведущий научный сотрудник</p></bio><bio xml:lang="en"><p>12, VNIIPO, Balashikha, Mosñow Region, 143903</p><p>Leonid M. MESHMAN, Candidate of Technical Sciences, Leading Researcher </p></bio><email xlink:type="simple">fire404@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Всероссийский научно-исследовательский институт противопожарной обороны МЧС России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>All-Russian Research Institute for Fire Protection</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2019</year></pub-date><pub-date pub-type="epub"><day>03</day><month>05</month><year>2019</year></pub-date><volume>28</volume><issue>2</issue><fpage>93</fpage><lpage>97</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Мешман Л.М., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Мешман Л.М.</copyright-holder><copyright-holder xml:lang="en">Meshman L.M.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/750">https://www.fire-smi.ru/jour/article/view/750</self-uri><abstract><p>Рассмотрены благоприятные факторы, способствующие эффективному тушению пожара, и неблагоприятные факторы, препятствующие эффективному тушению пожара. Представлено распределение расхода каждого оросителя и общего расхода АУП для различных вариантов распределительных сетей при последовательной активации всех оросителей, находящихся на каждой из защищаемых диктующих площадей, при общем расходе АУП не более 10 л/с и начальной интенсивности диктующего оросителя iнорм &gt; iрасч = 0,06 л/(с · м2) и iнорм = 0,08 л/(с · м2). Показано, что если правильно подобрать диаметры трубопроводов распределительной сети, то даже при нормативном значении интенсивности орошения диктующего оросителя общий расход АУП при активации четырех оросителей, рассчитанный по методике, приведенной в СП 5.13130.2009, может быть меньше нормативного значения примерно в 1,5 раза, за счет чего расширяется защищаемая диктующая площадь по сравнению с нормативной Sнорм = 60 м2.</p></abstract><trans-abstract xml:lang="en"><p>Consider the enabling factors that contribute to an effective fire fighting, and adverse factors that hinder effective fire fighting. The distribution of the flow rate of each irrigator and the total flow rate of AFES of different distribution networks with sequential activation of all irrigators located on each of the protected dictating areas, with the total flow rate of AFES not more than 10 l/s and at the initial intensity of the dictating sprinkler inorm &gt; icalc = 0.06 l/(sec · m2) and inorm = 0.08 l/(sec · m2). It is shown that if the diameters of the distribution network pipelines are chosen correctly, then even with the normative value of the intensity of irrigation of the dictating sprinkler, the total flow rate of the AFES with the activation of four irrigators, calculated according to the method given in Set of rules 5.13130.2009, may be less than the normative value by about 1.5 times due to which the protected dictating area is expanded compared to the normative Snorm = 60 m2.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>давление</kwd><kwd>расход</kwd><kwd>диктующий ороситель</kwd><kwd>интенсивность орошения</kwd><kwd>диктующая защищаемая площадь</kwd><kwd>эпюра орошения</kwd><kwd>эффективное тушение пожара</kwd></kwd-group><kwd-group xml:lang="en"><kwd>pressure</kwd><kwd>flow rate</kwd><kwd>dictating sprinkler</kwd><kwd>irrigation intensity</kwd><kwd>dictating protected area</kwd><kwd>irrigation plot</kwd><kwd>effective fire extinguishing</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">СП 5.13130.2009. Системы противопожарной защиты. Установки пожарной сигнализации и пожаротушения автоматические. Нормы и правила проектирования (ред. от 01.06.2011). URL: http://base.garant.ru/195658/ (дата обращения: 10.01.2019).</mixed-citation><mixed-citation xml:lang="en">СП 5.13130.2009. Системы противопожарной защиты. Установки пожарной сигнализации и пожаротушения автоматические. Нормы и правила проектирования (ред. от 01.06.2011). URL: http://base.garant.ru/195658/ (дата обращения: 10.01.2019).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Мешман Л. М. Частные вопросы при проектировании водяных АУП// Пожаровзрывобезопасность/ Fire and Explosion Safety. - 2019. - Т. 29, № 1. - С. 8 0 - 8 8 .</mixed-citation><mixed-citation xml:lang="en">Мешман Л. М. Частные вопросы при проектировании водяных АУП// Пожаровзрывобезопасность/ Fire and Explosion Safety. - 2019. - Т. 29, № 1. - С. 8 0 - 8 8 .</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">З.НПБ 88-2001*.Установки пожаротушения и сигнализации. Нормы и правила проектирования (с изм. № 1). URL: http://docs.cntd.ru/document/1200016069 (дата обращения: 10.01.2019).</mixed-citation><mixed-citation xml:lang="en">З.НПБ 88-2001*.Установки пожаротушения и сигнализации. Нормы и правила проектирования (с изм. № 1). URL: http://docs.cntd.ru/document/1200016069 (дата обращения: 10.01.2019).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Мешман Л. М., Былинкин В. А., Губин Р. Ю., Романова Е. Ю. Автоматические водяные и пенные установки пожаротушения. Проектирование : учеб.-метод, пособ. - М. : ВНИИПО, 2009. - 572 с.</mixed-citation><mixed-citation xml:lang="en">Мешман Л. М., Былинкин В. А., Губин Р. Ю., Романова Е. Ю. Автоматические водяные и пенные установки пожаротушения. Проектирование : учеб.-метод, пособ. - М. : ВНИИПО, 2009. - 572 с.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Мешман Л. М., Былинкин В. А., Губин Р. Ю., Романова Е. Ю. Оросители водяных и пенных автоматических установок пожаротушения : учеб.-метод, пособ. — М. : ВНИИПО, 2 0 0 2 . - 3 1 5 с.</mixed-citation><mixed-citation xml:lang="en">Мешман Л. М., Былинкин В. А., Губин Р. Ю., Романова Е. Ю. Оросители водяных и пенных автоматических установок пожаротушения : учеб.-метод, пособ. — М. : ВНИИПО, 2 0 0 2 . - 3 1 5 с.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
