<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.18322/PVB.2016.25.11.35-44</article-id><article-id custom-type="elpub" pub-id-type="custom">firesmi-615</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ПОЖАРНАЯ ОПАСНОСТЬ ЭЛЕКТРОТЕХНИЧЕСКИХ ИЗДЕЛИЙ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS</subject></subj-group></article-categories><title-group><article-title>Оценка тепловыделения при горении электрических кабелей</article-title><trans-title-group xml:lang="en"><trans-title>Heat release assessment at burning electric cables</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Барботько</surname><given-names>С. Л.</given-names></name><name name-style="western" xml:lang="en"><surname>Barbotko</surname><given-names>S. L.</given-names></name></name-alternatives><email xlink:type="simple">slbarbotko@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Вольный</surname><given-names>О. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Volnyy</surname><given-names>O. S.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Всероссийский научно-исследовательский институт авиационных материалов</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>16</day><month>05</month><year>2018</year></pub-date><volume>25</volume><issue>11</issue><fpage>35</fpage><lpage>44</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Барботько С.Л., Вольный О.С., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Барботько С.Л., Вольный О.С.</copyright-holder><copyright-holder xml:lang="en">Barbotko S.L., Volnyy O.S.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/615">https://www.fire-smi.ru/jour/article/view/615</self-uri><abstract><p>Проанализированы методы оценки тепловыделения при горении полимерных материалов; выбран метод испытаний. Определены характеристики тепловыделения при горении различных типов электрических проводов. В качестве испытательного оборудования выбран проточный калориметр типа OSU (ASTM E906), используемый при оценке пожарной опасности материалов авиационного назначения. Представлены результаты испытаний. Показано влияние различных составляющих на регистрируемые показатели. Описаны подходы к возможной оценке пожарной опасности электрических проводов и кабелей по характеристикам тепловыделения.</p></abstract><trans-abstract xml:lang="en"><p>Available cases of emergence and development of fires with participation of products show need of assessment of heat release when burning electric isolation of wires and comparisons according to this characteristic the electrocable products of different types. Definition of these characteristics possibly using different types of test equipment. Use of rated methods of determination of combustion heat or its direct definition by means of adiabatic bomb calorimeter is recognized inexpedient as in the conditions of fire there is no complete combustion of combustible component. Besides, these methods does not allow to receive information on kinetics of process of heat production. The cone-calorimeter widely applied abroad in different industries and working with using principle of oxygen consumption can give essential mistake depending on types of used fire retardants. In the aircraft manufacturing industry for heat release assessment at burning is used the OSU calorimeter (ASTM E906, type A) working with using the thermopair method. At carrying out researches the decision to use this type of the equipment and test method is made. Seven brands of the electricity cables differing both by structure of outer jacket, and the size of cross-section and quantity of current carrying veins have been tested. Tests of samples are carried out at heat flux on the sample of equal 35 kW/m2. The standard defined characteristic (the maximum intensity of heat release rate (kW/m2) has been counted for comparison not only the conditional square of sample, but also at wire length, the area of exterior surface, mass of cable. The total quantity of heat release has been defined for different intervals of time (1, 2 and 5 minutes) as in standard form for aircraft (kW·min/m2), and in metric system of measures (MJ/100 rm). Essential influence of structure and cable size on registered characteristics of heat release and prospects of use of this method for assessment of fire safety of electricity cables is shown.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>тепловыделение</kwd><kwd>провод</kwd><kwd>пожарная безопасность</kwd><kwd>проточный калориметр</kwd><kwd>кабель</kwd><kwd>heat release</kwd><kwd>wire</kwd><kwd>fire safety</kwd><kwd>OSU calorimeter</kwd><kwd>electric cable</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">История авиационного материаловедения.ВИАМ-80 лет: годы и люди / Под общ. ред. Е. Н. Каблова. -М. : ВИАМ, 2012.-С. 391-396.</mixed-citation><mixed-citation xml:lang="en">История авиационного материаловедения.ВИАМ-80 лет: годы и люди / Под общ. ред. Е. Н. Каблова. -М. : ВИАМ, 2012.-С. 391-396.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Каблов Е. Н. ВИАМ: продолжение пути // Наука в России. -2012. -№ 3. -С. 36-44.</mixed-citation><mixed-citation xml:lang="en">Каблов Е. Н. ВИАМ: продолжение пути // Наука в России. -2012. -№ 3. -С. 36-44.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Каблов Е. Н. Стратегические направления развития материалов и технологий их переработки на период до 2030 года // Авиационные материалы и технологии. -2012. -№ S. -С. 7-17.</mixed-citation><mixed-citation xml:lang="en">Каблов Е. Н. Стратегические направления развития материалов и технологий их переработки на период до 2030 года // Авиационные материалы и технологии. -2012. -№ S. -С. 7-17.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Smith E. E. Measuring rate of heat, smoke and toxic gas release // Fire Technology.-1972.-Vol. 8, Issue 3. -P. 237-245. DOI: 10.1007/bf02590547.</mixed-citation><mixed-citation xml:lang="en">Smith E. E. Measuring rate of heat, smoke and toxic gas release // Fire Technology.-1972.-Vol. 8, Issue 3. -P. 237-245. DOI: 10.1007/bf02590547.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Tewarson A. Heat release rate in fires // Fire and Materials.-1980.-Vol. 4, Issue 4.-P. 185-191. DOI: 10.1002/fam.810040405.</mixed-citation><mixed-citation xml:lang="en">Tewarson A. Heat release rate in fires // Fire and Materials.-1980.-Vol. 4, Issue 4.-P. 185-191. DOI: 10.1002/fam.810040405.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Krause R. F., Gann R. G. Rate of heat release measurements using oxygen consumption // Journal of Fire and Flammability. -1980.-Vol. 12, No. 2. -P. 117-130.</mixed-citation><mixed-citation xml:lang="en">Krause R. F., Gann R. G. Rate of heat release measurements using oxygen consumption // Journal of Fire and Flammability. -1980.-Vol. 12, No. 2. -P. 117-130.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Babrauskas V. Performance of the Ohio State University rate of heat release apparatus using polymethylmethacrylate and gaseous fuels // Fire Safety Journal.-1982.-Vol. 5, Issue 1.-P. 9-20. DOI: 10.1016/0379-7112(82)90003-0.</mixed-citation><mixed-citation xml:lang="en">Babrauskas V. Performance of the Ohio State University rate of heat release apparatus using polymethylmethacrylate and gaseous fuels // Fire Safety Journal.-1982.-Vol. 5, Issue 1.-P. 9-20. DOI: 10.1016/0379-7112(82)90003-0.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Tsuchiya Y. Methods of determining heat release rate: State-of-the-art // Fire Safety Journal.-1982. -Vol. 5, Issue 1. -P. 49-57. DOI: 10.1016/0379-7112(82)90006-6.</mixed-citation><mixed-citation xml:lang="en">Tsuchiya Y. Methods of determining heat release rate: State-of-the-art // Fire Safety Journal.-1982. -Vol. 5, Issue 1. -P. 49-57. DOI: 10.1016/0379-7112(82)90006-6.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Babrauskas V. Comparative rates of heat release from five different types of test apparatuses // Journal of Fire Sciences. -1986.-Vol. 4, No. 2.-P. 148-159. DOI: 10.1177/073490418600400208.</mixed-citation><mixed-citation xml:lang="en">Babrauskas V. Comparative rates of heat release from five different types of test apparatuses // Journal of Fire Sciences. -1986.-Vol. 4, No. 2.-P. 148-159. DOI: 10.1177/073490418600400208.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Цstman B. A.-L., Tsantaridis L. D. Heat release and classification of fire retardant wood products // Fire and Materials. -1995.-Vol. 19, Issue 6. -P. 253-258. DOI: 10.1002/fam.810190603.</mixed-citation><mixed-citation xml:lang="en">Цstman B. A.-L., Tsantaridis L. D. Heat release and classification of fire retardant wood products // Fire and Materials. -1995.-Vol. 19, Issue 6. -P. 253-258. DOI: 10.1002/fam.810190603.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Fritz T. W., Hunsberger P. L. Testing of mattress composites in the cone calorimeter // Fire and Materials. - 1997. - Vol. 21, Issue 1. - P. 17-22. DOI: 10.1002/(sici)1099-1018(199701)21:1&lt;17::aid-fam590&gt;3.0.co;2-g.</mixed-citation><mixed-citation xml:lang="en">Fritz T. W., Hunsberger P. L. Testing of mattress composites in the cone calorimeter // Fire and Materials. - 1997. - Vol. 21, Issue 1. - P. 17-22. DOI: 10.1002/(sici)1099-1018(199701)21:1&lt;17::aid-fam590&gt;3.0.co;2-g.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л. Тепловыделение при горении полимерных материалов авиационного назначения : автореф. дис. …канд. техн. наук. -М. : ВИАМ, 1999. -23 с.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л. Тепловыделение при горении полимерных материалов авиационного назначения : автореф. дис. …канд. техн. наук. -М. : ВИАМ, 1999. -23 с.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Barbotko S. L., Vorobyоv V. N. Influence of air flow in the OSU calorimeter on test results // Third International Aircraft Fire&amp;Cabin Research Conference, October 22-25, 2001. URL: http://www.fire.tc.faa.gov/2001Conference/files/TAInsulationSeatFlammability/BarbotkoPAPER.PDF (дата обращения: 05.07.2016).</mixed-citation><mixed-citation xml:lang="en">Barbotko S. L., Vorobyоv V. N. Influence of air flow in the OSU calorimeter on test results // Third International Aircraft Fire&amp;Cabin Research Conference, October 22-25, 2001. URL: http://www.fire.tc.faa.gov/2001Conference/files/TAInsulationSeatFlammability/BarbotkoPAPER.PDF (дата обращения: 05.07.2016).</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Marker T. Heat release and flammability testing of surrogate panels // Technical Report DOT/FAA/AR-TN01/112.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2001.-26 p.</mixed-citation><mixed-citation xml:lang="en">Marker T. Heat release and flammability testing of surrogate panels // Technical Report DOT/FAA/AR-TN01/112.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2001.-26 p.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Huiqing Zhang. Fire-Safe Polymers and Polymer Composites // Technical Report DOT/FAA/AR-04/11. -Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2004. -209 p.</mixed-citation><mixed-citation xml:lang="en">Huiqing Zhang. Fire-Safe Polymers and Polymer Composites // Technical Report DOT/FAA/AR-04/11. -Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2004. -209 p.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Lyon R. E., Blake D. Heat release rate of objects burning in cargo compartments // Technical Report DOT/FAA/AR-TN05/9. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2005. -11 p.</mixed-citation><mixed-citation xml:lang="en">Lyon R. E., Blake D. Heat release rate of objects burning in cargo compartments // Technical Report DOT/FAA/AR-TN05/9. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2005. -11 p.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Xin Liu, Quintiere J. G. Flammability properties of clay-nylon nanocomposites // Technical Report DOT/FAA/AR-07/29.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2007.-154 p.</mixed-citation><mixed-citation xml:lang="en">Xin Liu, Quintiere J. G. Flammability properties of clay-nylon nanocomposites // Technical Report DOT/FAA/AR-07/29.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2007.-154 p.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Quintiere J. G., Walters R. N., Crowley S. Flammability properties of aircraft carbon-fiber structural composite // Technical ReportDOT/FAA/AR-07/57.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2007. -49 p.</mixed-citation><mixed-citation xml:lang="en">Quintiere J. G., Walters R. N., Crowley S. Flammability properties of aircraft carbon-fiber structural composite // Technical ReportDOT/FAA/AR-07/57.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2007. -49 p.</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л. Моделирование процесса горения материалов при испытаниях по оценке тепловыделения // Пожаровзрывобезопасность. -2007. -Т. 16, № 3. -С. 10-24.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л. Моделирование процесса горения материалов при испытаниях по оценке тепловыделения // Пожаровзрывобезопасность. -2007. -Т. 16, № 3. -С. 10-24.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л. Прогнозирование на основе математической модели изменения кинетики тепловыделения при горении стеклопластика // Пожаровзрывобезопасность.-2008.-Т. 17,№5. -С. 23-28.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л. Прогнозирование на основе математической модели изменения кинетики тепловыделения при горении стеклопластика // Пожаровзрывобезопасность.-2008.-Т. 17,№5. -С. 23-28.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Walters R. N., Lyon R. E. Flammability of polymer composites // Technical ReportDOT/FAA/AR-08/18. -Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2008. -22 p.</mixed-citation><mixed-citation xml:lang="en">Walters R. N., Lyon R. E. Flammability of polymer composites // Technical ReportDOT/FAA/AR-08/18. -Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2008. -22 p.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л. Влияние толщины металлической подложки на кинетику тепловыделения при горении тонкослойных полимерных материалов // Пожаровзрывобезопасность.-2009.-Т. 18, № 7. -С. 45-50.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л. Влияние толщины металлической подложки на кинетику тепловыделения при горении тонкослойных полимерных материалов // Пожаровзрывобезопасность.-2009.-Т. 18, № 7. -С. 45-50.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Stoliarov S. I., Crowley S., Lyon R. E. Predicting the burning rates of noncharring polymers // Technical Report DOT/FAA/AR-TN09/16. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2009. -41 p.</mixed-citation><mixed-citation xml:lang="en">Stoliarov S. I., Crowley S., Lyon R. E. Predicting the burning rates of noncharring polymers // Technical Report DOT/FAA/AR-TN09/16. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2009. -41 p.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Stoliarov S. I., Crowley S., Walters R. N., Lyon R. E. Prediction of the burning rates of charring polymers // Technical Report DOT/FAA/AR-TN09/59. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2009. -29 p.</mixed-citation><mixed-citation xml:lang="en">Stoliarov S. I., Crowley S., Walters R. N., Lyon R. E. Prediction of the burning rates of charring polymers // Technical Report DOT/FAA/AR-TN09/59. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2009. -29 p.</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л., Асеева Р. М., Серков Б. Б., Сивенков А. Б., Круглов Е.Ю.Обопределении теплот сгорания и тепловыделения при горении полимерных материалов // Пожаровзрывобезопасность. -2012. -Т. 21, № 5. -С. 25-34.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л., Асеева Р. М., Серков Б. Б., Сивенков А. Б., Круглов Е.Ю.Обопределении теплот сгорания и тепловыделения при горении полимерных материалов // Пожаровзрывобезопасность. -2012. -Т. 21, № 5. -С. 25-34.</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Walters R. N., Lyon R. E. Microscale combustion calorimeter: interlaboratory study of precision and bias // Technical Report DOT/FAA/TC-12/39.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2012. -29 p.</mixed-citation><mixed-citation xml:lang="en">Walters R. N., Lyon R. E. Microscale combustion calorimeter: interlaboratory study of precision and bias // Technical Report DOT/FAA/TC-12/39.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2012. -29 p.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Шуркова Е. Н., Вольный О. С., Изотова Т. Ф., Барботько С. Л. Исследование возможности снижения тепловыделения при горении композиционного материала путем изменения его структуры // Авиационные материалы и технологии. -2012. -№ 1(22).-С. 27-30.</mixed-citation><mixed-citation xml:lang="en">Шуркова Е. Н., Вольный О. С., Изотова Т. Ф., Барботько С. Л. Исследование возможности снижения тепловыделения при горении композиционного материала путем изменения его структуры // Авиационные материалы и технологии. -2012. -№ 1(22).-С. 27-30.</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л., Кириллов В. Н., Шуркова Е. Н. Оценка пожарной безопасности полимерных композиционных материалов авиационного назначения // Авиационные материалы и технологии. -2012.-№ 3(24).-С. 56-63.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л., Кириллов В. Н., Шуркова Е. Н. Оценка пожарной безопасности полимерных композиционных материалов авиационного назначения // Авиационные материалы и технологии. -2012.-№ 3(24).-С. 56-63.</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Lyon R. E., Safronava N. A probabilistic analysis of pass/fail fire tests // Technical Report DOT/FAA/TC-12/13.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2013.-36 p.</mixed-citation><mixed-citation xml:lang="en">Lyon R. E., Safronava N. A probabilistic analysis of pass/fail fire tests // Technical Report DOT/FAA/TC-12/13.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2013.-36 p.</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л., Швец Н. И., Застрогина О. Б., Изотова Т.Ф. Исследование влияния толщины стеклопластиков на характеристики тепловыделения при горении // Пожаровзрывобезопасность. -2013.-Т. 22, № 7. -С. 30-36.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л., Швец Н. И., Застрогина О. Б., Изотова Т.Ф. Исследование влияния толщины стеклопластиков на характеристики тепловыделения при горении // Пожаровзрывобезопасность. -2013.-Т. 22, № 7. -С. 30-36.</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Скрылев Н. С., Вольный О. С., Постнов В. И., Барботько С. Л. Исследование влияния тепловых факторов климата на изменение характеристик пожаробезопасности полимерных композиционных материалов // ТрудыВИАМ.-2013.-№9, ст. 5.-C. 23-28.URL:http://www.viam-works.ru (дата обращения: 23.06.2016).</mixed-citation><mixed-citation xml:lang="en">Скрылев Н. С., Вольный О. С., Постнов В. И., Барботько С. Л. Исследование влияния тепловых факторов климата на изменение характеристик пожаробезопасности полимерных композиционных материалов // ТрудыВИАМ.-2013.-№9, ст. 5.-C. 23-28.URL:http://www.viam-works.ru (дата обращения: 23.06.2016).</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Lyon R. E., Walters R. N., Stoliarov S. I., Safronava N. Principles and practice of microscale combustion calorimetry // Technical Report DOT/FAA/TC-12/53, R1.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2014. -95 p.</mixed-citation><mixed-citation xml:lang="en">Lyon R. E., Walters R. N., Stoliarov S. I., Safronava N. Principles and practice of microscale combustion calorimetry // Technical Report DOT/FAA/TC-12/53, R1.-Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2014. -95 p.</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Скрылев Н. С., Вольный О. С., Абрамов Д. В., Шуркова Е. Н. Исследование влияния тепловлажностных факторов на изменение характеристик пожарной безопасности ПКМ, подверженных климатическим воздействиям // Труды ВИАМ.-2014.-№7, ст. 12. URL: http://www.viam-works.ru (дата обращения: 23.06.2016). DOI: 10.18577/2307-6046-2014-0-7-12-12.</mixed-citation><mixed-citation xml:lang="en">Скрылев Н. С., Вольный О. С., Абрамов Д. В., Шуркова Е. Н. Исследование влияния тепловлажностных факторов на изменение характеристик пожарной безопасности ПКМ, подверженных климатическим воздействиям // Труды ВИАМ.-2014.-№7, ст. 12. URL: http://www.viam-works.ru (дата обращения: 23.06.2016). DOI: 10.18577/2307-6046-2014-0-7-12-12.</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Safronava N., Lyon R. E., Crowley S., Stoliarov S. I. Effect of moisture on ignition time of polymers // Technical Report DOT/FAA/TC-TN14/53. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2015. -29 p.</mixed-citation><mixed-citation xml:lang="en">Safronava N., Lyon R. E., Crowley S., Stoliarov S. I. Effect of moisture on ignition time of polymers // Technical Report DOT/FAA/TC-TN14/53. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2015. -29 p.</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Lyon R. E., Fulmer M., Walters R., Crowley S. Effect of airflow and measurement method on the heat release rate of aircraft cabin materials in the Ohio State University apparatus // Technical Report DOT/FAA/TC-TN15/34. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2016. -20 p.</mixed-citation><mixed-citation xml:lang="en">Lyon R. E., Fulmer M., Walters R., Crowley S. Effect of airflow and measurement method on the heat release rate of aircraft cabin materials in the Ohio State University apparatus // Technical Report DOT/FAA/TC-TN15/34. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2016. -20 p.</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Reinhardt J. W. Development of an improved fire test method and criteria for aircraft electrical wiring // Technical Report DOT/FAA/AR-10/2. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2010. -95 p.</mixed-citation><mixed-citation xml:lang="en">Reinhardt J. W. Development of an improved fire test method and criteria for aircraft electrical wiring // Technical Report DOT/FAA/AR-10/2. - Federal Aviation Administration, William J. Hughes Technical Center Airport and Aircraft Safety, 2010. -95 p.</mixed-citation></citation-alternatives></ref><ref id="cit37"><label>37</label><citation-alternatives><mixed-citation xml:lang="ru">Авиационные правила. Часть 25. Самолеты транспортной категории. 3-я ред. с попр. 1-7 / Межгосударственный авиационный комитет. -М. : ОАО “Авиаиздат”, 2014. -278 с.</mixed-citation><mixed-citation xml:lang="en">Авиационные правила. Часть 25. Самолеты транспортной категории. 3-я ред. с попр. 1-7 / Межгосударственный авиационный комитет. -М. : ОАО “Авиаиздат”, 2014. -278 с.</mixed-citation></citation-alternatives></ref><ref id="cit38"><label>38</label><citation-alternatives><mixed-citation xml:lang="ru">Lyon R. E. Fire Calorimetry (Technical ReportDOT/FAA/CT-95/46).-NJ : Federal Aviation Administration, Atlantic City Intl. Airport, 1995.-200 p.</mixed-citation><mixed-citation xml:lang="en">Lyon R. E. Fire Calorimetry (Technical ReportDOT/FAA/CT-95/46).-NJ : Federal Aviation Administration, Atlantic City Intl. Airport, 1995.-200 p.</mixed-citation></citation-alternatives></ref><ref id="cit39"><label>39</label><citation-alternatives><mixed-citation xml:lang="ru">Перельман В. И. Краткий справочник химика. -М. : Химия, 1951. -326 с.</mixed-citation><mixed-citation xml:lang="en">Перельман В. И. Краткий справочник химика. -М. : Химия, 1951. -326 с.</mixed-citation></citation-alternatives></ref><ref id="cit40"><label>40</label><citation-alternatives><mixed-citation xml:lang="ru">Корольченко А. Я., Корольченко Д. А. Пожаровзрывоопасность веществ и материалов и средства их тушения : справочник: в 2 ч. - 2-е изд. -М. : Пожнаука, 2004. -Ч. I. -С. 98-105.</mixed-citation><mixed-citation xml:lang="en">Корольченко А. Я., Корольченко Д. А. Пожаровзрывоопасность веществ и материалов и средства их тушения : справочник: в 2 ч. - 2-е изд. -М. : Пожнаука, 2004. -Ч. I. -С. 98-105.</mixed-citation></citation-alternatives></ref><ref id="cit41"><label>41</label><citation-alternatives><mixed-citation xml:lang="ru">Mouritz A. P., Gibson A. G. Fire properties of polymer composite materials.-Dordrecht, Netherlands : Springer, 2006.-398 p.</mixed-citation><mixed-citation xml:lang="en">Mouritz A. P., Gibson A. G. Fire properties of polymer composite materials.-Dordrecht, Netherlands : Springer, 2006.-398 p.</mixed-citation></citation-alternatives></ref><ref id="cit42"><label>42</label><citation-alternatives><mixed-citation xml:lang="ru">Барботько С. Л., Шуркова Е. Н., Вольный О. С., Скрылёв Н. С. Оценка пожарной безопасности полимерных композиционных материалов для внешнего контура авиационной техники // Авиационные материалы и технологии. -2013. -№ 1(26).-С. 56-59.</mixed-citation><mixed-citation xml:lang="en">Барботько С. Л., Шуркова Е. Н., Вольный О. С., Скрылёв Н. С. Оценка пожарной безопасности полимерных композиционных материалов для внешнего контура авиационной техники // Авиационные материалы и технологии. -2013. -№ 1(26).-С. 56-59.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
