<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.18322/PVB.2016.25.08.27-33</article-id><article-id custom-type="elpub" pub-id-type="custom">firesmi-575</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОГНЕСТОЙКОСТЬ СТРОИТЕЛЬНЫХ КОНСТРУКЦИЙ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>FIRE-RESISTANCE OF BUILDING CONSTRUCTIONS</subject></subj-group></article-categories><title-group><article-title>ОСОБЕННОСТИ ОГНЕЗАЩИТЫ СВЕТОПРОЗРАЧНЫХ КОНСТРУКЦИЙ ПРИ ПОМОЩИ ВОДЯНОГО ОРОШЕНИЯ</article-title><trans-title-group xml:lang="en"><trans-title>FEATURES OF THE FIRE PROTECTION TRANSPARENT CONSTRUCTIONS WITH WATER IRRIGATION</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Казиев</surname><given-names>М. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Kaziev</surname><given-names>M. M.</given-names></name></name-alternatives><email xlink:type="simple">kaziev01@bk.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Зубкова</surname><given-names>Е. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Zubkova</surname><given-names>E. V.</given-names></name></name-alternatives><email xlink:type="simple">zubkova.agps@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Безбородов</surname><given-names>В. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Bezborodov</surname><given-names>V. I.</given-names></name></name-alternatives><email xlink:type="simple">vladimirvniipo@mail.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Академия ГПС МЧС России</institution><country>Russian Federation</country></aff><aff xml:lang="ru" id="aff-2"><institution>Оренбургский филиал ВНИИПО МЧС России</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2016</year></pub-date><pub-date pub-type="epub"><day>16</day><month>05</month><year>2018</year></pub-date><volume>25</volume><issue>8</issue><fpage>27</fpage><lpage>33</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Казиев М.М., Зубкова Е.В., Безбородов В.И., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Казиев М.М., Зубкова Е.В., Безбородов В.И.</copyright-holder><copyright-holder xml:lang="en">Kaziev M.M., Zubkova E.V., Bezborodov V.I.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/575">https://www.fire-smi.ru/jour/article/view/575</self-uri><abstract><p>Проведен анализ крупных пожаров, происшедших в 2016 г. в ОАЭ. Определены пути снижения масштабов пожара в высотных зданиях. Отмечено преимущество использования водяного орошения в качестве защиты светопрозрачных конструкций (СПК) в условиях пожара. Рассмотрено влияние водяного орошения на пожароустойчивость светопрозрачных конструкций с огнестойким стеклом и триплексом. Представлен обзор результатов испытаний СПК с огнестойким стеклом и триплексом на крупномасштабной установке. Выявлены особенности защиты светопрозрачных конструкций водяным орошением.</p></abstract><trans-abstract xml:lang="en"><p>Major fires, that occurred in the UAE this year, revealed the incapability of existing systems to prevent the spread of fire on the facade of the building. Thus, the main aim to prevent the spread of fire is the location of the fire inside the building and prevention of fire spreading outside the building through the translucent constructions. The most difficult task, solving this problem, is to confirm the necessity of sufficient fire resistance of the translucent constructions, which do not allow spread the fire outside and spread through the building. The existing methods of high-rise building assessment do not fully reveal the actual fire resistance state. One of the factors that may reduce the fire resistance of translucent constructions is water spraying, if the system is incorrectly installed. At the present time, there is no data on the effect of water spraying on the fire resistance of translucent constructions with fire-resistant filling and not enough information on the reaction of constructions with laminated glass. In this regard, in order to determine the influence of water spraying on the fire resistance of fire-resistant glass, we have conducted fire testing of the samples of translucent constructions on large-scale setup, which consisted of two stages. At the first stage, the samples of TC without water spraying were tested, and at the second stage, the samples of TC with water spraying on the unheated side. Conducted large-scale fire testing of the fire-resistant glass showed, that the presence of water spraying on the unheated surface leads to the glass cracking, to the violation of the mechanism of dehydration and foaming of the fire retardant gel and its water washout. Ultimately, all this contributes to premature destruction of the fire-resistant glass. Laminated glass testing revealed that water spraying of the unheated side does not significantly increases the fire resistance of laminated glass “3-1-3”, it was only 9 minutes in standard fire temperature conditions. The greatest efficiency was shown by water spraying the heated surface of the laminated glass. In this case, the water spraying prevents the heating and melting of the protection layer and helps to preserve the integrity of the sample. Another necessary condition is to ensure even water spraying the entire heated surface of laminated glass. Thus, the conducted tests allow make following conclusions. 1) water spraying the unheated side of the fire-resistant glass with a water soluble fire retardant gel can cause loss of fire resistance and premature destruction of translucent constructions; 2) water spraying the unheated side of the laminated glass model of “3-1-3” does not significantly increase the fire resistance of the TC, due to inadequate protection for lamination from warming up and melting; 3) the most effective way to improve the fire resistance of TC is continuous and even water spraying the heated side of the laminated glass. In this case, the melting of the polymer film is excluded. The use of the obtained results of this research in practice will improve the fire safety of buildings with translucent designs.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>пожароустойчивость</kwd><kwd>светопрозрачные конструкции</kwd><kwd>водяное орошение</kwd><kwd>огнестойкое стекло</kwd><kwd>триплекс</kwd><kwd>высотные здания</kwd><kwd>крупномасштабные испытания</kwd><kwd>fire resistance</kwd><kwd>translucent constructions</kwd><kwd>water spraying</kwd><kwd>fire-resistant glass</kwd><kwd>laminated glass</kwd><kwd>high-rise buildings</kwd><kwd>large-scale fire testing</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Есин В. М., Калмыков С. П. К вопросу расчета температуры продуктов горения, удаляемых из коридоров зданий // Пожаровзрывобезопасность. - 2016. - Т. 25, № 1. - С. 47-53. DOI: 10.18322/PVB.2016.25.01.47-53.</mixed-citation><mixed-citation xml:lang="en">Есин В. М., Калмыков С. П. К вопросу расчета температуры продуктов горения, удаляемых из коридоров зданий // Пожаровзрывобезопасность. - 2016. - Т. 25, № 1. - С. 47-53. DOI: 10.18322/PVB.2016.25.01.47-53.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Moukhallati D. Short circuit on spotlight blamed for the Address Downtown Dubai hotel fire. URL: http://www.thenational.ae/uae/short-circuit-on-spotlight-blamed-for-the-address-downtown-dubaihotel- fire (дата обращения: 20.04.2016).</mixed-citation><mixed-citation xml:lang="en">Moukhallati D. Short circuit on spotlight blamed for the Address Downtown Dubai hotel fire. URL: http://www.thenational.ae/uae/short-circuit-on-spotlight-blamed-for-the-address-downtown-dubaihotel- fire (дата обращения: 20.04.2016).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Полиция назвала причину пожара в отеле-небоскребе Дубая. URL: http://rian.com.ua/world/news/20160120/1003860716.html (дата обращения: 15.04.2016).</mixed-citation><mixed-citation xml:lang="en">Полиция назвала причину пожара в отеле-небоскребе Дубая. URL: http://rian.com.ua/world/news/20160120/1003860716.html (дата обращения: 15.04.2016).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Ajman building fire victims fear they “lost everything”. URL: http://gulfnews.com/news/uae/emergencies/ajman-building-fire-victims-fear-they-lost-everything-1.1699718 (дата обращения: 10.05.2016).</mixed-citation><mixed-citation xml:lang="en">Ajman building fire victims fear they “lost everything”. URL: http://gulfnews.com/news/uae/emergencies/ajman-building-fire-victims-fear-they-lost-everything-1.1699718 (дата обращения: 10.05.2016).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Firefighters battle huge blaze at Ajman tower near Dubai. URL: http://www.theguardian.com/world/2016/mar/28/major-fire-breaks-ajman-tower-dubai-uae (дата обращения: 17.05.2016).</mixed-citation><mixed-citation xml:lang="en">Firefighters battle huge blaze at Ajman tower near Dubai. URL: http://www.theguardian.com/world/2016/mar/28/major-fire-breaks-ajman-tower-dubai-uae (дата обращения: 17.05.2016).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Безбородов В. И., Казиев М. М., Зубкова Е. В. Навесные светопрозрачные фасадные системы: конструктивные особенности и противопожарное нормирование // Пожарная безопасность.- 2016. -№ 1. -С. 103-109.</mixed-citation><mixed-citation xml:lang="en">Безбородов В. И., Казиев М. М., Зубкова Е. В. Навесные светопрозрачные фасадные системы: конструктивные особенности и противопожарное нормирование // Пожарная безопасность.- 2016. -№ 1. -С. 103-109.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Гравит М. В. Распространение результатов испытаний на огнестойкость светопрозрачных ограждающих ненесущих конструкций // Пожаровзрывобезопасность.-2014.-Т. 23,№ 11. -С. 42-45.</mixed-citation><mixed-citation xml:lang="en">Гравит М. В. Распространение результатов испытаний на огнестойкость светопрозрачных ограждающих ненесущих конструкций // Пожаровзрывобезопасность.-2014.-Т. 23,№ 11. -С. 42-45.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Хасанов И. Р., Еремина Т. Ю., Гравит М. В., Макеев А. А. Использование принципа расширенного применения результатов испытаний строительных конструкций и материалов в европейской системе нормирования пожарной безопасности // Архитектура и строительство России. - 2013. -№ 3. -С. 24-28.</mixed-citation><mixed-citation xml:lang="en">Хасанов И. Р., Еремина Т. Ю., Гравит М. В., Макеев А. А. Использование принципа расширенного применения результатов испытаний строительных конструкций и материалов в европейской системе нормирования пожарной безопасности // Архитектура и строительство России. - 2013. -№ 3. -С. 24-28.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Wu C.W., Lin T. H., Lei M. Y., Chung T. H., Huang C. C., Chiang W. T. Fire test on a non-heat-resistant fireproof glass with down-flowing water film // Fire Safety Science.-2005.-No. 8.-P. 327-338. DOI: 10.3801/IAFSS.FSS.8-327.</mixed-citation><mixed-citation xml:lang="en">Wu C.W., Lin T. H., Lei M. Y., Chung T. H., Huang C. C., Chiang W. T. Fire test on a non-heat-resistant fireproof glass with down-flowing water film // Fire Safety Science.-2005.-No. 8.-P. 327-338. DOI: 10.3801/IAFSS.FSS.8-327.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Wu C. W., Lin T. H., Lei M. Y., Chung T. H., Huang C. C., Chiang W. T. Fire resistance tests of a glass pane with down-flowing water film // Journal of the Chinese Institute of Engineers. - 2008. - Vol. 31, Issue 5. -P. 737-744. DOI: 10.1080/02533839.2008.9671428.</mixed-citation><mixed-citation xml:lang="en">Wu C. W., Lin T. H., Lei M. Y., Chung T. H., Huang C. C., Chiang W. T. Fire resistance tests of a glass pane with down-flowing water film // Journal of the Chinese Institute of Engineers. - 2008. - Vol. 31, Issue 5. -P. 737-744. DOI: 10.1080/02533839.2008.9671428.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Shao Quan, Li Fang, Chen Tao, Sun Zhan-hui. Heat resistance and water protection effectiveness for large single-pane fireproof glass // Journal of Central South University of Technology. - 2011. - Vol. 18, Issue 6. -P. 2185-2191. DOI: 10.1007/s11771-011-0961-6.</mixed-citation><mixed-citation xml:lang="en">Shao Quan, Li Fang, Chen Tao, Sun Zhan-hui. Heat resistance and water protection effectiveness for large single-pane fireproof glass // Journal of Central South University of Technology. - 2011. - Vol. 18, Issue 6. -P. 2185-2191. DOI: 10.1007/s11771-011-0961-6.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Malcomson R. W. Report on Window Sprinkler Systems : Report No. NC529.-Northbrook, IL : Underwriters Laboratories Inc., 1969.</mixed-citation><mixed-citation xml:lang="en">Malcomson R. W. Report on Window Sprinkler Systems : Report No. NC529.-Northbrook, IL : Underwriters Laboratories Inc., 1969.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Richardson J. K., Oleszkiewicz I. Fire tests on window assemblies protected by automatic sprinklers // Fire Technology.-1987.-Vol. 23, No. 2. -P. 115-132. DOI: 10.1007/BF01040427.</mixed-citation><mixed-citation xml:lang="en">Richardson J. K., Oleszkiewicz I. Fire tests on window assemblies protected by automatic sprinklers // Fire Technology.-1987.-Vol. 23, No. 2. -P. 115-132. DOI: 10.1007/BF01040427.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Kim A. K., Taber B. C., Lougheed G. D. Sprinkler protection of exterior glazing // Fire Technology.- 1998. -Vol. 34, No. 2. -P. 116-138. DOI: 10.1023/A:1015325418666.</mixed-citation><mixed-citation xml:lang="en">Kim A. K., Taber B. C., Lougheed G. D. Sprinkler protection of exterior glazing // Fire Technology.- 1998. -Vol. 34, No. 2. -P. 116-138. DOI: 10.1023/A:1015325418666.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Kim A. K., Lougheed G. D. Fire protection of windows using sprinklers // Construction Technology Update. -1997.-No. 12. -P. 4-10.</mixed-citation><mixed-citation xml:lang="en">Kim A. K., Lougheed G. D. Fire protection of windows using sprinklers // Construction Technology Update. -1997.-No. 12. -P. 4-10.</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Казиев М. М., Зубкова Е. В., Безбородов В. И. Защита триплекса при пожаре с помощью водяного орошения // Пожаровзрывобезопасность. -2015. -Т. 24, № 3. -С. 32-36</mixed-citation><mixed-citation xml:lang="en">Казиев М. М., Зубкова Е. В., Безбородов В. И. Защита триплекса при пожаре с помощью водяного орошения // Пожаровзрывобезопасность. -2015. -Т. 24, № 3. -С. 32-36</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
