<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">firesmi-407</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>СНИЖЕНИЕ ЭФФЕКТИВНОСТИ СИСТЕМЫ ДЫМОУДАЛЕНИЯ С ИСКУССТВЕННЫМ ПОБУЖДЕНИЕМ ПРИ ВОЗНИКНОВЕНИИ "ПОДДУВА"</article-title><trans-title-group xml:lang="en"><trans-title>REDUCING OF EFFICIENCY OF SMOKE REMOVAL SYSTEM WITH ARTIFICIAL IMPULSE DURING "PLUGHOLING"</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Пузач</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Puzach</surname><given-names>S. V.</given-names></name></name-alternatives><email xlink:type="simple">puzachsv@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Тунг</surname><given-names>ДО ТХАНЬ</given-names></name><name name-style="western" xml:lang="en"><surname>Tung</surname><given-names>DO THANH</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Хай</surname><given-names>НГУЕН ТХАНЬ</given-names></name><name name-style="western" xml:lang="en"><surname>Hai</surname><given-names>NGUYEN THANH</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Академия ГПС МЧС России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>State Fire Academy of Emercom of Russia</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Институт пожарной безопасности МОБ Вьетнама</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Institute of Fire Safety MOB Vietnam</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2015</year></pub-date><pub-date pub-type="epub"><day>15</day><month>05</month><year>2018</year></pub-date><volume>24</volume><issue>5</issue><fpage>54</fpage><lpage>60</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Пузач С.В., Тунг Д.Т., Хай Н.Т., 2018</copyright-statement><copyright-year>2018</copyright-year><copyright-holder xml:lang="ru">Пузач С.В., Тунг Д.Т., Хай Н.Т.</copyright-holder><copyright-holder xml:lang="en">Puzach S.V., Tung D.T., Hai N.T.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/407">https://www.fire-smi.ru/jour/article/view/407</self-uri><abstract><p>Разработана модифицированная зонная модель расчета термогазодинамики пожара в условиях работы системы дымоудаления с искусственным побуждением с учетом возникновения "поддува". Выполнено сопоставление зависимостей скорости опускания нижней границы задымленного нагретого припотолочного газового слоя от времени с момента начала пожара, полученных с использованием предложенной зонной и полевой моделей. Показано, что эффективность работы системы дымоудаления существенно снижается при возникновении "поддува". Обнаружено, что для предотвращения "поддува" для каждого расхода вентилятора системы дымоуда-ления существует критическое минимальное значение площади дымоудаляющего отверстия, которое существенно зависит от толщины припотолочного слоя в момент включения дымоуда-ления.</p></abstract><trans-abstract xml:lang="en"><p>Efficiency of smoke removal systems may be reduced due to the phenomenon of "plugholing", which lies in the fact that the clean air out under ceiling smoke layer due to the action of lift forces passes through the smoke ejection hole. Amodified zone model for calculation of thermal and gas dynamics of fire under action of a smoke removal system with artificial impulse during "plugholing" is proposed. Reducing the flow rate of a mixture of gases and smoke leaving from under ceiling layer outside the room is taken into account by introducing the rate coefficient. A numerical study of thermal dynamics picture of fire in the model room with model combustible load by using the modified zone model and a three-dimensional field model is made. It is considered the room in the form of a parallelepiped with dimensions of 30x25x15 m. Combustible material is turbine oil. Volumetric flow rate of fan of smoke removal system are 30000, 60000 and 90000 m3/h. Dependencies between velocity of lowering the bottom border of the under ceiling layer and the time of fire, that obtained with the use of the modified zone model and a three-dimensional field model, are compared. It is shown that the smoke removal system efficiency is significantly reduced when "plugholing" is occurred. The flow rate of a mixture of gases and smoke leaving from under ceiling layer outside the room is 2 times less than in the case of the absence of "plugholing". It is found that to prevent "plugholing" in the case of smoke removal system with artificial impulse for each fan there is critical minimum square of the hole of smoke removal system, which essentially depends on the thickness of under ceiling layer at the time of the beginning of system work.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>пожар</kwd><kwd>дымоудаление</kwd><kwd>смешанная конвекция</kwd><kwd>поддув</kwd><kwd>припотолочный слой</kwd><kwd>fire</kwd><kwd>smoke removal</kwd><kwd>mixed convection</kwd><kwd>plugholing</kwd><kwd>temperature of under ceiling layer</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Viot J., Vauquelin O., Rhodes N. Characterization of the plug-holing phenomenon for the exhausting of a low density gas layer // 14th Australasion Fluid Mechanics Conference. - Adelaide University, Adelaide, Australia, 10-14 December 2001. - P. 529 - 532.</mixed-citation><mixed-citation xml:lang="en">Viot J., Vauquelin O., Rhodes N. Characterization of the plug-holing phenomenon for the exhausting of a low density gas layer // 14th Australasion Fluid Mechanics Conference. - Adelaide University, Adelaide, Australia, 10-14 December 2001. - P. 529 - 532.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Chow W. K., Li /.Review on design guides for smoke management system in an atrium // International Journal on Engineering Performance - Based Fire Codes. - 2005. - Vol. 7, No. 2. - P. 65-87.</mixed-citation><mixed-citation xml:lang="en">Chow W. K., Li /.Review on design guides for smoke management system in an atrium // International Journal on Engineering Performance - Based Fire Codes. - 2005. - Vol. 7, No. 2. - P. 65-87.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Linjie Li, Zihe Gao, Jie Ji, Jianyun Han, Jinhua Sun. Research on the phenomenon of plug-holing under mechanical smoke exhaust in tunnel fire / 9th Asia-Oceania Symposium on Fire Science and Technology //ProcediaEngineering. -2013. -Vol. 62. -P. 1112-1120. doi: 10.1016/j.proeng.2013.08.168.</mixed-citation><mixed-citation xml:lang="en">Linjie Li, Zihe Gao, Jie Ji, Jianyun Han, Jinhua Sun. Research on the phenomenon of plug-holing under mechanical smoke exhaust in tunnel fire / 9th Asia-Oceania Symposium on Fire Science and Technology //ProcediaEngineering. -2013. -Vol. 62. -P. 1112-1120. doi: 10.1016/j.proeng.2013.08.168.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Пузач С. В., До Тхань Тунг. Условия возникновения "поддува" при работе систем дымоудаления с естественным побуждением//Пожаровзрывобезопасность.-2014. - Т. 23, № 9. - С. 57-63.</mixed-citation><mixed-citation xml:lang="en">Пузач С. В., До Тхань Тунг. Условия возникновения "поддува" при работе систем дымоудаления с естественным побуждением//Пожаровзрывобезопасность.-2014. - Т. 23, № 9. - С. 57-63.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Пузач С. В., До Тхань Тунг. Влияние высоты стенки дымоудаляющего отверстия на возникновение "поддува" при дымоудалении с естественным побуждением // Пожаровзрывобезопасность. - 2014.-Т. 23, № 11. -С. 46-51.</mixed-citation><mixed-citation xml:lang="en">Пузач С. В., До Тхань Тунг. Влияние высоты стенки дымоудаляющего отверстия на возникновение "поддува" при дымоудалении с естественным побуждением // Пожаровзрывобезопасность. - 2014.-Т. 23, № 11. -С. 46-51.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Chow W.K. Determination of the smoke layer interface height for hot smoke tests in big halls // Journal of Fire Sciences. -2009. - Vol. 27, No. 2. - P. 125-142. doi: 10.1177/0734904108096852.</mixed-citation><mixed-citation xml:lang="en">Chow W.K. Determination of the smoke layer interface height for hot smoke tests in big halls // Journal of Fire Sciences. -2009. - Vol. 27, No. 2. - P. 125-142. doi: 10.1177/0734904108096852.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Кошмаров Ю. А. Прогнозирование опасных факторов пожара в помещении. - М. : Академия ГПС МВД России, 2000. - 118 с.</mixed-citation><mixed-citation xml:lang="en">Кошмаров Ю. А. Прогнозирование опасных факторов пожара в помещении. - М. : Академия ГПС МВД России, 2000. - 118 с.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">International Building Code. - International Code Council, Inc., 2003. URL: http://publicecodes.cy-berregs.com/icod/ibc/2003/index.htm (дата обращения: 10.02.2015).</mixed-citation><mixed-citation xml:lang="en">International Building Code. - International Code Council, Inc., 2003. URL: http://publicecodes.cy-berregs.com/icod/ibc/2003/index.htm (дата обращения: 10.02.2015).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Пузач С. В., Хай Нгуен Тхань. О достоверности применения эмпирических формул расчета массового расхода системы дымоудаления при пожаре в атриуме // Пожаровзрывобезопасность. - 2009. - Т. 18, №№ 9. - С. 35-43.</mixed-citation><mixed-citation xml:lang="en">Пузач С. В., Хай Нгуен Тхань. О достоверности применения эмпирических формул расчета массового расхода системы дымоудаления при пожаре в атриуме // Пожаровзрывобезопасность. - 2009. - Т. 18, №№ 9. - С. 35-43.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Корн Г.,Корн Т. Справочник по математике для научных работников и инженеров.-М. : Наука, 1968. -720 с.</mixed-citation><mixed-citation xml:lang="en">Корн Г.,Корн Т. Справочник по математике для научных работников и инженеров.-М. : Наука, 1968. -720 с.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Пузач С. В. Методы расчета тепломассообмена при пожаре в помещении и их применение при решении практических задач пожаровзрывобезопасности. - М. : Академия ГПС МЧС России, 2005. -336 с.</mixed-citation><mixed-citation xml:lang="en">Пузач С. В. Методы расчета тепломассообмена при пожаре в помещении и их применение при решении практических задач пожаровзрывобезопасности. - М. : Академия ГПС МЧС России, 2005. -336 с.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Патанкар С. Численные методы решения задач теплообмена и динамики жидкости. - М. : Энергоатомиздат, 1984. - 152 с.</mixed-citation><mixed-citation xml:lang="en">Патанкар С. Численные методы решения задач теплообмена и динамики жидкости. - М. : Энергоатомиздат, 1984. - 152 с.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Свидетельство о государственной регистрации программы для ЭВМ № 2006614238 от 08.12.2006 г. Интегральные, зонные и полевые методы расчета динамики опасных факторов пожара / Пузач С. В. - М. : Федеральная служба по интеллектуальной собственности (Роспатент), 2006.</mixed-citation><mixed-citation xml:lang="en">Свидетельство о государственной регистрации программы для ЭВМ № 2006614238 от 08.12.2006 г. Интегральные, зонные и полевые методы расчета динамики опасных факторов пожара / Пузач С. В. - М. : Федеральная служба по интеллектуальной собственности (Роспатент), 2006.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">McGrattan K., Klein В., Hostikka S., Floyd J. Fire Dynamics Simulator (Version 5) User's Guide. NIST Special Publication 1019-5. - Gaithersburg, Maryland, USA : National Institute of Standards and Technology, 2007. - 186 p.</mixed-citation><mixed-citation xml:lang="en">McGrattan K., Klein В., Hostikka S., Floyd J. Fire Dynamics Simulator (Version 5) User's Guide. NIST Special Publication 1019-5. - Gaithersburg, Maryland, USA : National Institute of Standards and Technology, 2007. - 186 p.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
