<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.22227/0869-7493.2024.33.01.5-14</article-id><article-id custom-type="elpub" pub-id-type="custom">firesmi-1317</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЩИЕ ВОПРОСЫ КОМПЛЕКСНОЙ БЕЗОПАСНОСТИ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>GENERAL QUESTIONS OF COMPLEX SAFETY</subject></subj-group></article-categories><title-group><article-title>Апробация и анализ нормативных требований по защите лестничных клеток с открытыми проемами при распространении пожара по фасаду</article-title><trans-title-group xml:lang="en"><trans-title>Approbation and analysis of regulatory requirements for protection of stairwells with open doorways in case of fire propagation along the facade</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2396-3136</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Пехотиков</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Pekhotikov</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>ПЕХОТИКОВ Андрей Владимирович, канд. техн. наук, начальник отдела огнестойкости строительных конструкций и инженерного оборудования</p><p>143903, Московская обл., г. Балашиха, мкр. ВНИИПО, 12</p></bio><bio xml:lang="en"><p>Andrey V. PEKHOTIKOV, Cand. Sci. (Eng.), Head of Department of Fire Resistance of Building Structures and Engineering Equipment</p><p>VNIIPO, 12, Balashikha, Moscow Region, 143903</p></bio><email xlink:type="simple">Pekhotikov.a@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-6347-3257</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Абашкин</surname><given-names>А. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Abashkin</surname><given-names>A. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>АБАШКИН Александр Анатольевич, начальник отдела моделирования пожаров и нестандартного проектирования</p><p>143903, Московская обл., г. Балашиха, мкр. ВНИИПО, 12</p></bio><bio xml:lang="en"><p>Alexander A. ABASHKIN, Head of Fire Modeling and Custom Design Department</p><p>VNIIPO, 12, Balashikha, Moscow Region, 143903</p></bio><email xlink:type="simple">one_15@bk.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-9660-9221</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Гомозов</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Gomozov</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>ГОМОЗОВ Александр Васильевич, канд. техн. наук, старший научный сотрудник отдела огнестойкости строительных конструкций и инженерного оборудования</p><p>143903, Московская обл., г. Балашиха, мкр. ВНИИПО, 12</p></bio><bio xml:lang="en"><p>Alexander V. GOMOZOV, Cand. Sci. (Eng.), Senior Researcher, Department of Fire Resistance of Building Structures and Engineering Equipment</p><p>VNIIPO, 12, Balashikha, Moscow Region, 143903</p></bio><email xlink:type="simple">Gomozovav@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2313-6309</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Лучкин</surname><given-names>С. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Luchkin</surname><given-names>S. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>ЛУЧКИН Сергей Алексеевич, младший научный сотрудник отдела огнестойкости строительных конструкций и инженерного оборудования</p><p>143903, Московская обл., г. Балашиха, мкр. ВНИИПО, 12</p></bio><bio xml:lang="en"><p>Sergey Alekseevich LUCHKIN, Junior Researcher, Department of Fire Resistance of Building Structures and Engineering Equipment</p><p>VNIIPO, 12, Bala­shikha, Moscow Region, 143903</p></bio><email xlink:type="simple">Luchkin.sergey@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Всероссийский ордена «Знак Почета» научно-исследовательский институт противопожарной обороны Министерства Российской Федерации по делам гражданской обороны, чрезвычайным ситуациям и ликвидации последствий стихийных бедствий</institution><country>Россия</country></aff><aff xml:lang="en"><institution>All-Russian Research Institute for Fire Protection of Ministry of Russian Federation for Civil Defense, Emergencies and Elimination of Consequences of Natural Disasters</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>27</day><month>02</month><year>2024</year></pub-date><volume>33</volume><issue>1</issue><fpage>5</fpage><lpage>14</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Пехотиков А.В., Абашкин А.А., Гомозов А.В., Лучкин С.А., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Пехотиков А.В., Абашкин А.А., Гомозов А.В., Лучкин С.А.</copyright-holder><copyright-holder xml:lang="en">Pekhotikov A.V., Abashkin A.A., Gomozov A.V., Luchkin S.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/1317">https://www.fire-smi.ru/jour/article/view/1317</self-uri><abstract><sec><title>Введение</title><p>Введение. Положениями Федерального закона Российской Федерации от 22.07.2008 г. № 123-ФЗ «Технический регламент о требованиях пожарной безопасности» предусмотрена возможность проектирования лестничных клеток типа Л1 с открытыми проемами в наружных стенах, а требованиями нормативных документов предусмотрена необходимость расчетного обоснования проектных решений по исключению блокирования лестничных клеток опасными факторами пожара, распространяющимися по фасаду.</p><p>Для апробации и анализа этих требований в настоящей статье проведена оценка влияния различных факторов на время блокирования таких лестничных клеток опасными факторами пожара.</p></sec><sec><title>Цели и задачи</title><p>Цели и задачи. Целью настоящей статьи является апробация и анализ нормативных требований по защите лестничных клеток с открытыми проемами от блокирования опасными факторами пожара в зависимости от скорости ветра, класса функциональной пожарной опасности горящего помещения, размеров простенков и выступов лестничной клетки, а также конструктивного исполнения окон горящих помещений.</p></sec><sec><title>Методы</title><p>Методы. Расчеты временных интервалов блокирования лестничных клеток опасными факторами пожара, распространяющимися по фасаду из окон горящих помещений, базировались на методологических положениях и математических моделях, используемых для определения пожарного риска.</p></sec><sec><title>Результаты</title><p>Результаты. Получены расчетные данные, позволяющие оценить временные интервалы блокирования опасными факторами пожара лестничных клеток с открытыми проемами в наружных стенах в зависимости от скорости ветра в районе размещения объекта, особенностей горючей нагрузки в горящем помещении, размеров простенков и выступов лестничной клетки, а также конструктивного исполнения окон горящих помещений. Эти данные позволили оценить необходимость уточнения нормативных требований.</p></sec><sec><title>Выводы</title><p>Выводы. На основе исследований получены расчетные данные для формирования необходимого практического опыта обоснования требований по исключению блокирования лестничных клеток с открытыми проемами опасными факторами пожара, которые распространяются по фасаду из окон горящих помещений. Полученные данные позволяют оценить влияние скорости ветра, класса функциональной пожарной опасности горящего помещения, размера выступа лестничной клетки на время ее блокирования опасными факторами пожара, а также определить направления уточнения нормативных требований.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Introduction</title><p>Introduction. The provisions of the Federal Law of the Russian Federation dated 22.07.2008 No. 123-FZ “Technical Regulations on Fire Safety Requirements” stipulate the possibility of designing L1 type stairwells with open doorways in external walls. The requirements of regulatory documents stipulate the necessity of calculation substantiation of design solutions to exclude blocking of stairwells by fire hazardous factors spreading along the facade. To test and analyze these requirements, this paper assesses the influence of different factors on the time of blocking of such stairwells by fire hazardous factors.</p></sec><sec><title>Goals and objectives</title><p>Goals and objectives. The purpose of this paper is to approve and analyze regulatory requirements for the protection of stairwells with open doorways from blocking by fire hazardous factors depending on the wind speed, the functional fire hazard class of the burning premises, the dimensions of partitions and projections of the stairwell, as well as the design of the windows of the burning premises.</p></sec><sec><title>Methods</title><p>Methods. Calculations of time intervals of stairwell blocking by fire hazardous factors spreading along the facade from the windows of burning premises were based on methodological provisions and mathematical models used to determine fire risk.</p></sec><sec><title>Results</title><p>Results. The calculated data allowing to estimate time intervals of blocking stairwells with open doorways in external walls by fire hazardous factors depending on the wind speed in the area of object location, peculiarities of combustible load in the burning premises, sizes of partitions and projections of the stairwell, as well as the design of windows of burning premises were obtained. These data made it possible to assess the necessity of specifying regulatory requirements.</p></sec><sec><title>Conclusions</title><p>Conclusions. Based on the research, calculated data for formation of necessary practical experience of substantiation of the requirements on exclusion of stairwells blocking with open doorways by fire hazardous factors that spread along the facade from the windows of burning premises are received. The obtained data make it possible to evaluate the influence of wind speed, the functional fire hazard class of burning premises, the size of the stairwell projection on the time of its blocking by fire hazardous factors, as well as to determine the directions of specification of regulatory requirements.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>размер простенка</kwd><kwd>размер выступа</kwd><kwd>предельные значения</kwd><kwd>опасные факторы пожара</kwd><kwd>помещение с естественным проветриванием</kwd></kwd-group><kwd-group xml:lang="en"><kwd>partition size</kwd><kwd>projection size</kwd><kwd>limit values</kwd><kwd>fire hazardous factors</kwd><kwd>naturally ventilated premises</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">СП 7.13130.2013. Отопление, вентиляция и кондиционирование. Противопожарные требования. Изменение № 1. URL: www.standards.ru</mixed-citation><mixed-citation xml:lang="en">SP 7.13130.2013. Heating, ventilation and air conditioning. Fire safety requirements. Change No. 1. URL: www.standards.ru</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">СП 2.13130.2020. Системы противопожарной защиты. Обеспечение огнестойкости объектов защиты. URL: www.standards.ru</mixed-citation><mixed-citation xml:lang="en">SP 2.13130.2020. Fire protection systems. Ensuring the fire resistance of objects of protection. Change 1. URL: www.standards.ru</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">СП 1.13130.2020. Системы противопожарной защиты. Эвакуационные пути и выходы. URL: www.standards.ru</mixed-citation><mixed-citation xml:lang="en">SP 1.13130.2020. Fire protection systems. Evacuation routes and exits. URL: www.standards.ru</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ Р 53309. Здания и фрагменты зданий. Метод натурных огневых испытаний. Общие требования.</mixed-citation><mixed-citation xml:lang="en">GOST R 53309. Buildings and fragments of buildings. Method of full-scale fire tests. General requirements.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Методика определения расчетных величин пожарного риска в зданиях, сооружениях и пожарных отсеках различных классов функциональной пожарной опасности (в ред. приказа МЧС от 14.11.2022 № 1140). URL: www.standards.ru</mixed-citation><mixed-citation xml:lang="en">Methodology for determining the calculated values of fire risk in buildings, structures and fire compartments of various classes of functional fire hazard (ed. dated 11.14.2022 No. 1140). URL: www.standards.ru</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">СП 131.13330.2020. Строительная климатология.</mixed-citation><mixed-citation xml:lang="en">SP 131.13330.2020. Construction climatology.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">СП 60.13330.2020. Отопление, вентиляция и кондиционирование.</mixed-citation><mixed-citation xml:lang="en">SP 60.13330.2020. Heating, ventilation and air conditioning.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">ГОСТ 23166–2021. Конструкции оконные и балконные светопрозрачные ограждающие.</mixed-citation><mixed-citation xml:lang="en">GOST 23166–2021. Window and balcony translucent enclosing structures.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Ярош А.С., Чалаташвили М.Н., Кроль А.Н., Попова Е.А., Романова В.В., Сачков А.В. Анализ математических моделей развития опасных факторов пожара в системе зданий и сооружений // Вестник научного центра по безопасности работ в угольной промышленности. 2019. № 1. С. 50–56.</mixed-citation><mixed-citation xml:lang="en">Yarosh A.S., Chalatashvili M.N., Krol’ A.N., Popova E.A., Romanova V.V., Sachkov A.V. Analysis of mathematical models for the development of dangerous fire factors in the system of buildings and structures. Bulletin of the Scientific Center for the Safety of Work in the Coal Industry. 2019; 1:50-56. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Дроздов Д.С., Дроздова Т.И. Графическое моделирование для оценки опасных факторов пожара // Техно­генная и природная безопасность : сб. науч. тр. V междунар. науч.-практ. конф. Саратов, 24–26 апреля 2019 г. / под ред. С.М. Рогачевой, А.С. Жутова, И.М. Учаевой. Саратов : Амирит, 2019. С. 69–73.</mixed-citation><mixed-citation xml:lang="en">Drozdov D.S., Drozdova T.I. Graphic modeling for assessing fire hazards. Tekhnogennaya i prirodnaya bezopasnost : collection scientific works V international scientific and practical conference. Saratov, April 24–26, 2019. C.M. Rogacheva, A.S. Zhutova, I.M. Uchaeva (ed.). Saratov, Amirit Publ., 2019; 69-73. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Бедрина Е.А., Рекин А.С., Храпский С.Ф., Бокарев А.И., Денисова Е.С. Прогнозирование динамики тепломассообменных процессов при пожарах в типовых многоэтажных жилых зданиях // Динамика систем, механизмов и машин. 2019. Т. 7. № 3. С. 10–15. DOI: 10.25206/2310-9793-7-3-10-15</mixed-citation><mixed-citation xml:lang="en">Bedrina E.A., Rekin A.S., Khrapskiy S.F., Bokarev A.I., Denisova E.S. Forecasting the dynamics of heat and mass transfer processes during fires in typical multi-storey residential buildings. Dynamics of Systems, Mechanisms and Machines. 2019; 7(3):10-15. DOI: 10.25206/2310-9793-7-3-10-15 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Хасанов И.Р., Зуев С.А., Абашкин А.А., Зуева А.С. Распространение пожара из открытой автостоянки, расположенной на первом этаже жилого здания // Пожаровзрывобезопасность/Fire and Explosion Safety. 2022. Т. 31. № 1. С. 77–87. DOI: 10.22227/0869-7493.2022.31.01.77-87</mixed-citation><mixed-citation xml:lang="en">Khasanov I.R., Zuev S.A., Abashkin A.A., Zuevа A.S. The spread of fi re from an open car park on the ground floor of a residential building. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2022; 31(1):77-87. DOI: 12.22227/0869-7493.2022.31.01.77-87 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">McGrattan K., Miles S. Modeling ﬁres using Computational Fluid Dynamics (CFD). SFPE Handbook of Fire Protection Engineering. Chapter 32. Fifth Edition // Society of Fire Protection Engineers. 2016. Pp. 1034–1065. DOI: 10.1007/978-1-4939-2565-0</mixed-citation><mixed-citation xml:lang="en">McGrattan K., Miles S. Modeling ﬁres using Computational Fluid Dynamics (CFD). SFPE Handbook of Fire Protection Engineering. Chapter 32. 5th ed. Society of Fire Protection Engineers. 2016; 1034-1065. DOI: 10.1007/978-1-4939-2565-0</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Nuclear Safety NEA/CSNI/R Investigating heat and smoke propagation mechanisms in multi-compartment fire scenarios. Final Report of the PRISME Project. 14.01.2018.</mixed-citation><mixed-citation xml:lang="en">Nuclear Safety NEA/CSNI/R. Investigating heat and smoke propagation mechanisms in multi-compartment fire scenarios. Final Report of the PRISME Project. 14.01.2018.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">McGrattan K., Hostikka S., McDermott R. et al. Fire dynamics simulator user’s guide. National Institute of Standards and Technology, 2019. 288 p. URL: https://www.thunderheadeng.com/wpcontent/uploads/2013/08/FDS</mixed-citation><mixed-citation xml:lang="en">McGrattan K., Hostikka S., McDermott R. et al. Fire dynamics simulator user’s guide. National Institute of Standards and Technology, 2019; 288. URL: https://www.thunderheadeng.com/wpcontent/uploads/2013/08/FDS</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Gilbert S. Human Behavior in Home Fires, Technical Note (NIST TN). National Institute of Standards and Technology, Gaithersburg, MD, 2021. 28 р. DOI: 10.6028/NIST.TN.2191</mixed-citation><mixed-citation xml:lang="en">Gilbert S. Human Behavior in Home Fires, Technical Note (NIST TN). National Institute of Standards and Technology,</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang T., Wang Z., Wong H., Tam W., Huang X., Xiao F. Real-time forecast of compartment fire and flashover based on deep learning // Fire Safety Journal. 2022. No. 130. Р. 103579. DOI: 10.1016/j.firesaf.2022.103579</mixed-citation><mixed-citation xml:lang="en">Gaithersburg, MD, 2021; 28. DOI: 10.6028/NIST.TN.2191</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Cortés D., Gil D., Azorín J., Vandecasteele F., Verstockt S. A review of modelling and simulation methods for flashover prediction in confined space fires // Applied Sciences (Switzerland). 2020. No. 10 (16). Р. 5609. DOI: 10.3390/app10165609</mixed-citation><mixed-citation xml:lang="en">Zhang T., Wang Z., Wong H., Tam W., Huang X., Xiao F. Real-time forecast of compartment fire and flashover based on deep learning. Fire Safety Journal. 2022; 130:103579. DOI: 10.1016/j.firesaf.2022.103579</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Wu X., Zhang X., Huang X., Xiao F., Usmani A. A real-time forecast of tunnel fire based on numerical database and artificial intelligence // Building Simulation. 2022. No. 15. Рр. 511–524. DOI: 10.1007/s12273-021-0775-x</mixed-citation><mixed-citation xml:lang="en">Cortés D., Gil D., Azorín J., Vandecasteele F., Verstockt S. A review of modelling and simulation methods for flashover prediction in confined space fires. Applied Sciences (Switzerland). 2020; 10(16):5609. DOI: 10.3390/app10165609</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Leventon I., Bonny J. Influence of dispositional and situational factors on human perceptions of fire Risk. Interflam 2019. London. DOI: 10.1002/fam.2857</mixed-citation><mixed-citation xml:lang="en">Wu X., Zhang X., Huang X., Xiao F., Usmani A. A real-time forecast of tunnel fire based on numerical database and artificial intelligence. Building Simulation. 2022; 15:511-524. DOI: 10.1007/s12273-021-0775-x</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Gwynne S., Kuligowski E., Kinsey M., Hulse L. Modelling and Influencing Human Behaviour in Fire // Fire and Materials. 2017. Vol. 41. Issue 5. DOI: 10.1002/fam.2391</mixed-citation><mixed-citation xml:lang="en">Leventon I., Bonny J. Influence of Dispositional and Situational Factors on Human Perceptions of Fire Risk. Interflam 2019, London. DOI: 10.1002/fam.2857</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Gwynne S., Kuligowski E., Kinsey M., Hulse L. Modelling and influencing human behaviour in fire. Fire and Materials. 2017; 41(5). DOI: 10.1002/fam.2391</mixed-citation><mixed-citation xml:lang="en">Gwynne S., Kuligowski E., Kinsey M., Hulse L. Modelling and influencing human behaviour in fire. Fire and Materials. 2017; 41(5). DOI: 10.1002/fam.2391</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
