<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">firesmi</journal-id><journal-title-group><journal-title xml:lang="ru">Пожаровзрывобезопасность/Fire and Explosion Safety</journal-title><trans-title-group xml:lang="en"><trans-title>Pozharovzryvobezopasnost/Fire and Explosion Safety</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">0869-7493</issn><issn pub-type="epub">2587-6201</issn><publisher><publisher-name>ФГБОУ ВО «Национальный исследовательский Московский государственный строительный университет»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.22227/0869-7493.2022.31.06.30-46</article-id><article-id custom-type="elpub" pub-id-type="custom">firesmi-1177</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>МАТЕМАТИЧЕСКОЕ МОДЕЛИРОВАНИЕ, ЧИСЛЕННЫЕ МЕТОДЫ И КОМПЛЕКСЫ ПРОГРАММ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>MATHEMATICAL MODELING, NUMERICAL METHODS AND PROGRAM COMPLEXES</subject></subj-group></article-categories><title-group><article-title>Моделирование номограмм прогрева стальных конструкций с огнезащитными покрытиями различной толщины (на воде)</article-title><trans-title-group xml:lang="en"><trans-title>Simulation of nomograms showing the heating of steel structures with flame retardant coatings of different thicknesses (in the water)</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-2361-6428</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Корольченко</surname><given-names>Д. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Korolchenko</surname><given-names>D. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>КОРОЛЬЧЕНКО­ Дмитрий­ Александрович, д­р техн. наук, доцент, директор Института комплексной безопасности в строительстве</p><p>129337, г. Москва, Ярославское шоссе, 26</p><p>РИНЦ ID: 352067; Scopus Author ID: 55946060600; ResearcherID: E­1862­2017</p></bio><bio xml:lang="en"><p>Dmitriy­ A.­ KOROLCHENKO, Dr. Sci. (Eng.), Docent, Head of Institute of Complex Safety in Construction</p><p>Yaroslavskoe Shosse, 26, Moscow, 129337</p><p>ID RISC: 352067; Scopus Author ID: 55946060600; ResearcherID: E­1862­2017</p></bio><email xlink:type="simple">ikbs@mgsu.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-1427-606X</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Еремина</surname><given-names>Т. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Eremina</surname><given-names>T. Yu.</given-names></name></name-alternatives><bio xml:lang="ru"><p>ЕРЕМИНА ­Татьяна ­Юрьевна, д­р техн. наук, профессор, профессор кафедры комплексной безопасности в строительстве</p><p>129337, г. Москва, Ярославское шоссе, 26</p><p>РИНЦ ID: 274777; Scopus Author ID: 56893573700</p></bio><bio xml:lang="en"><p>Tatyana­ Yu.­ EREMINA, Dr. Sci. (Eng.), Professor, Professor of Department of Integrated Safety in Civil Engineering</p><p>Yaroslavskoe Shosse, 26, Moscow, 129337</p><p>ID RISC: 274777; Scopus Author ID: 56893573700</p></bio><email xlink:type="simple">main@stopfire.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-7234-1339</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Пузач</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Puzach</surname><given-names>S. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>ПУЗАЧ­ Сергей­ Викторович, д­р. техн. наук, профессор, заслуженный деятель науки РФ, профессор кафедры комплексной безопасности в строительстве</p><p>129337, г. Москва, Ярославское шоссе, 26</p><p>РИНЦ ID: 18265; ResearcherID: U­2907­2019; Scopus Author ID: 7003537835</p></bio><bio xml:lang="en"><p>Sergey­ V.­ PUZACH,­ Dr. Sci. (Eng.), Professor, Honoured Scientist of the Russian Federation, Professor of Department of Integrated Safety in Civil Engineering</p><p>Yaroslavskoe Shosse, 26, Moscow, 129337</p><p>ID RISC: 18265; ResearcherID: U­2907­2019; Scopus Author ID: 7003537835</p></bio><email xlink:type="simple">puzachsv@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-7409-0844</contrib-id><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Портнов</surname><given-names>Ф. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Portnov</surname><given-names>F. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>ПОРТНОВ­ Федор­ Александрович, канд. техн. наук, доцент кафедры комплексной безопасности в строительстве</p><p>129337, г. Москва, Ярославское шоссе, 26</p><p>РИНЦ ID: 1134480; Scopus Author ID: 57192372795</p></bio><bio xml:lang="en"><p>Fedor­ A.­ PORTNOV, Cand. Sci. (Eng.), Associated Professor of Department of Integrated Safety in Civil Engineering</p><p>Yaroslavskoe Shosse, 26, Moscow, 129337</p><p>ID RISC: 1134480; Scopus Author ID: 57192372795</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Национальный исследовательский Московский государственный строительный университет</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Moscow State University of Civil Engineering (National Research University)</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2022</year></pub-date><pub-date pub-type="epub"><day>02</day><month>02</month><year>2023</year></pub-date><volume>31</volume><issue>6</issue><fpage>30</fpage><lpage>46</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Корольченко Д.А., Еремина Т.Ю., Пузач С.В., Портнов Ф.А., 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">Корольченко Д.А., Еремина Т.Ю., Пузач С.В., Портнов Ф.А.</copyright-holder><copyright-holder xml:lang="en">Korolchenko D.A., Eremina T.Y., Puzach S.V., Portnov F.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.fire-smi.ru/jour/article/view/1177">https://www.fire-smi.ru/jour/article/view/1177</self-uri><abstract><sec><title>Введение</title><p>Введение. Стальные конструкции при высокотемпературном воздействии деформируются, теряют устойчивость и несущую способность, в результате чего происходит обрушение конструкций с последующим обрушением здания. Известно, что для увеличения пределов огнестойкости стальных конструкций до R 90 и R 120 часто используют вспучивающиеся краски. Но огнезащитная эффективность вспучивающихся красок при длительной эксплуатации недостаточно изучена, и применение такого вида огнезащитной обработки для несущих стальных конструкций требует обоснования. Для обеспечения устойчивости здания с требуемым пределом огнестойкости конструкций актуальным является изучение технологических факторов, влияющих на огнестойкость стальных конструкций со вспучивающимися красками на водной основе.</p></sec><sec><title>Цель работы</title><p>Цель работы. Разработка подходов к моделированию номограмм прогрева стальных конструкций с огнезащитными покрытиями различной толщины на водной основе. Были решены следующие задачи:</p></sec><sec><title>Методы исследования</title><p>Методы исследования. Для анализа теплофизических характеристик огнезащитных материалов использовали анализатор термических констант Hot Disk TPS 1500. С помощью термического анализа производилось исследование свойств огнезащитных материалов, а также происходящих в них физико-химических преобразований при программированном воздействии температуры и с применением специализированной аппаратуры термического анализа. Изучение эффективности средств огнезащиты для стальных конструкций проводилось в соответствии с ГОСТ Р 53295–2009 «Средства огнезащиты для стальных конструкций. Общие требования. Метод определения огнезащитной эффективности».</p><p>Результаты и их обсуждение. В результате исследований был разработан подход к прогнозированию огнестойкости строительных конструкций в виде построения блок-схемы исследования, на основании которой производится выбор функциональных критериев. На основе получения экспериментальных исследований возможно построение математических зависимостей огнестойкости от показателей, которые являются функциональными критериями. В частности, при оценке огнестойкости стальных конструкций проводится прогнозирование на основе теплофизических показателей. В работе впервые предложено введение функции огнезащитного материала в стандартный расчет огнестойкости при решении статической и теплофизической задач. На основе полученных данных приведены уравнения зависимости толщины сухого слоя огнезащитного материала от требуемого предела огнестойкости конструкции и номограмма прогрева защищенных стальных конструкций с огнезащитными покрытиями различной толщины.</p></sec><sec><title>Выводы</title><p>Выводы. По итогам проведенных исследований получены фундаментальные взаимосвязи динамики изменения структуры огнезащитного материала при тепловом воздействии на предел огнестойкости строительной конструкции на основе выбора функционального критерия. На основании экспериментальных исследований свойств и эффективности огнезащитных материалов разработана математическая модель зависимости толщины сухого слоя огнезащитных материалов от требуемого предела огнестойкости и теплофизических характеристик огнезащитных материалов.</p></sec></abstract><trans-abstract xml:lang="en"><sec><title>Introduction</title><p>Introduction. High temperatures cause deformation of steel structures which also lose stability and the bearing capacity, resulting in the collapse of structures with the subsequent collapse of the building. It is understood that intumescent paints are often used to increase the fire-resistance limits of steel structures up to R 90 and R 120. However the fire protection effectiveness of intumescent paints has not been sufficiently studied for the case of the long-term operation, and the application of this type of fire protection treatment of bearing steel structures requires justification. To ensure the building stability, coupled with the required fire resistance limit of structures, one should study the engineering factors affecting the fire resistance of steel structures that have intumescent paint coatings.</p><p>Purpose of the research work. Development of approaches to simulation of nomograms demonstrating the heating of steel structures with flame retardant coatings of different thicknesses. The research work solved the following tasks:</p></sec><sec><title>Research methods</title><p>Research methods. Hot Disk TPS 1500 thermal constant analyzer was used to analyze the thermo-physical characteristics of flame retardant materials. Thermal analysis was used to study the properties of flame retardants, as well as physical and chemical transformations occurring inside them under the programmed exposure to temperature effects and with the use of specialized thermal analysis equipment. The study of the fire protection efficiency for steel structures was conducted in accordance with GOST R (Russian State Standard) 53295–2009 “Fire protection means for steel structures. General requirements. The method of fire protection efficiency determination”.</p><p>Results and their discussion. As a result of the research, an approach to prediction of the fire resistance of building structures was developed in the form of a research flowchart, used to choose the functional criteria. Experimental studies were conducted to identify mathematical dependences between the fire resistance and the indicators, which serve as functional criteria. In particular, when assessing the fire resistance of steel structures, a prediction is made on the basis of thermos-physical indicators. The authors were first to propose the introduction of the function of fire protection materials into the standard pattern of fire resistance analysis in the course of solving static and thermo-physical problems. The obtained data were used to make equations of dependence between the thickness of a dry layer of a fire-retardant material, the required fire-resistance limit of a structure, and the nomogram showing the heating of protected steel structures with fire-retardant coatings of various thicknesses.</p></sec><sec><title>Conclusions</title><p>Conclusions. The results of the studies allowed identifying fundamental relationships between the dynamics of change in the structure of fire-retardant materials under the thermal effect and the fire resistance limit of a building structure on the basis of the choice of a functional criterion. Experimental studies of the properties and effectiveness of fire-resistant materials were conducted to develop a mathematical model showing dependence between the thickness of the dry layer of fire-resistant materials, the required fire-resistance limit and thermal-physical characteristics of fire-resistant materials.</p></sec></trans-abstract><kwd-group xml:lang="ru"><kwd>огнестойкость строительных конструкций</kwd><kwd>расчет предела огнестойкости</kwd><kwd>математическое моделирование</kwd><kwd>несущая способность</kwd><kwd>средства огнезащиты</kwd></kwd-group><kwd-group xml:lang="en"><kwd>fire resistance of building structures</kwd><kwd>analysis of the fire resistance limit</kwd><kwd>mathematical modelling</kwd><kwd>bearing capacity</kwd><kwd>fire protection materials</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">работа выполнена при финансовой поддержке Министерства науки и высшего образования Российской Федерации (проект «Теоретическая и экспериментальная разработка новых композиционных материалов для обеспечения безопасности при эксплуатации зданий и сооружений в условиях техногенной и биогенной угроз» #FSWG-2020-0007)</funding-statement><funding-statement xml:lang="en">this work was financially supported by the Ministry of Science and Higher Education of the Russian Federation (project «Theoretical and experimental design of new composite materials to ensure safety during the operation of buildings and structures under conditions of technogenic and biogenic threats»  #FSWG-2020-0007)</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Теличенко В.И., Ройтман В.М. Обеспечение стойкости зданий и сооружений при комбинированных особых воздействиях с участием пожара — базовый элемент системы комплексной безопасности // Повышение безопасности зданий и сооружений в процессе строительства и эксплуатации : мат. 1­го Национального конгрес са «Комплексная безопасность в строительстве 2010», 18–21 мая 2010 г., Москва, ВВЦ. Вып. 9. М., 2010. С. 15–29.</mixed-citation><mixed-citation xml:lang="en">Telichenko V.I., Roitman V.M. Ensuring the resilience of buildings and structures under combined special impacts including fire: the basic element of the system of integrated safety. Rising the  safety of buildings and structures during construction and operation  : materials Proceedings of the  1st National Congress “Integrated safety in construction 2010”, May 18–21, 2010, Moscow, All-Russia Exhibition Center. Issue 9. Moscow, 2010; 15-29. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Ройтман В.М., Приступюк Д.Н. Особенности оценки стойкости зданий и сооружений из железобетонных конструкций при комбинированных особых воздействиях с участием пожара // Пожаровзрывобезопасность/Fire and Explosion Safety. 2010. Т. 19. № 7. С. 29–38. URL: https://www.elibrary.ru/item.asp?id=15188713</mixed-citation><mixed-citation xml:lang="en">Roitman V.M., Prystupyuk D.N. Features of the estimation of buildings and constructions resistance from reinforced concrete designs at the combined hazardous effects with fire participation. Pozharovzryvobezopasnost/Fire and Explosion Safety. 2010; 19(7):29-38. URL: https://www.elibrary.ru/item.asp?id=15188713 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Wang Y., Goransson U., Holmstedt G., Omrane A. A model for prediction of temperature in steel structure protected by intumescent coating, based on tests in the cone calorimeter // Fire Safety Science. 2005. Vol. 8. Pp. 235–246. DOI: 10.3801/IAFSS.FSS.8­235</mixed-citation><mixed-citation xml:lang="en">Wang Y., Goransson U., Holmstedt G., Omrane A. A model for prediction of temperature in steel structure protected by intumescent coating, based on tests in the cone calorimeter. Fire Safety Science. 2005; 8:235-246. DOI: 10.3801/IAFSS.FSS.8-235</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">CMD (Construction Market Data). The market for fire protection of steel frames total market (beams and columns) by Types of Fire Protection, Great Britain, 2001–2014. URL: http://www.cmdgroup.com_February_2015.</mixed-citation><mixed-citation xml:lang="en">CMD (Construction Market Data). The market for fire protection of steel frames total market (beams and columns) by types of fire protection, Great Britain, years 2001–2014. 2015. URL: http://www.cmdgroup.com</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Голованов В.И., Кузнецова Е.В. Эффективные средства огнезащиты для стальных и железо бетонных конструкций // Промышленное и гражданское строительство. 2015. № 9. С. 82–90. URL: https://www.elibrary.ru/item.asp?id=24229215</mixed-citation><mixed-citation xml:lang="en">Golovanov V.I., Kuznetsova E.V. Effective means of fire protection for steel and concrete structures. Industrial and Civil Engineering. 2015; 9:82-90. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Голованов В.И., Пехотиков А.В., Павлов В.В. Оценка огнезащитной эффективности покрытий для стальных конструкций // Пожарная безопасность. 2020. № 4. С. 43–54. DOI: 10.37657/vniipo.pb.2020.101.4.004</mixed-citation><mixed-citation xml:lang="en">Golovanov V.I., Pekhotikov A.V., Pavlov V.V. Evaluation of fire-retardant effectiveness of coatings for steel structures. Pozharnaya Bezopasnost’/Fire Safety. 2020; 4:43-54. DOI: 10.37657/vniipo.pb.2020.101.4.004 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Ушанов В.В., Фадеев В.Е., Харитонов В.С., Щелкунов В.И., Павловский А.В., Косачев А.А. Огнестойкость и пожарная опасность сэндвич­ панелей и предложения по внесению изменений в нормативные правовые акты по пожарной безопасности в части их применения в зданиях и сооружениях различного функционального назначения // Пожарная безопасность. 2016. № 4. С. 119–122. URL: https://www.elibrary.ru/item.asp?id=27521504</mixed-citation><mixed-citation xml:lang="en">Ushanov V.V., Fadeev V.E., Kharitonov V.S., Shchelkunov V.I., Pavlovsky A.V., Kosachev A.A. Fire resistance and fire hazard of sandwich panels and the proposals on amendments to the normative legal acts on fire safety regarding their application in buildings and structures of various functionality. Pozharnaya Bezopasnost’/Fire Safety. 2016; 4:119­122. (rus). URL: https://www.elibrary.ru/item.asp?id=27521504</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Фадеев В.Е. Совершенствование современных методов испытаний на огнестойкость на основе внедрения гармонизированных европейских стандартов // Актуальные проблемы пожарной безопасности : мат. XXVIII Междунар. науч.­практ. конф. М. : ВНИИПО, 2016. Ч. 1. С. 305–309. URL: https://www.elibrary.ru/item.asp?id=28817893</mixed-citation><mixed-citation xml:lang="en">Fadeev V.E. Improvement of modern methods of fire resistance tests on the basis of the introduction of harmonized European standards. Actual Problems  of Fire Safety: Materials of the 28th International Science and Practical Conference. Moscow, VNIIPO, 2016; 1:305­309. URL: https://www.elibrary.ru/item.asp?id=28817893 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Шаталин С.С., Варламов A.B., Зыбина O.A., Мнацаканов С.С. О связующих в огнезащитных вспучивающихся композициях // Дизайн. Материалы. Технология. 2014. № 4 (34). С. 37–40.</mixed-citation><mixed-citation xml:lang="en">Shatalin S.S., Varlamov A.V., Zybina O.A., Mnatsakanov S.S. On binders in flame retardant intumescent compositions. Design. Materials. Technology. 2014; 4(34):37­40. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Завьялов Д.Е., Зыбина О.А., Митрофанов В.В., Мнацаканов С.С. Сравнительное изучение поведения фосфатов аммония в огнезащитных вспучивающихся композициях // Журнал прикладной химии. 2012. Т. 85. Вып. 1. С. 157–159. URL: https://www.elibrary.ru/item.asp?id=43912070</mixed-citation><mixed-citation xml:lang="en">Zavyalov D.E., Zybina O.A., Mitrofanov V.V., Mnatsakanov S.S. Comparative study of the behaviour of ammonium phosphates in flame retardant intumescent compositions. Russian Journal of Applied Chemistry. 2012; 85(1):157­159. URL: https://www.elibrary.ru/item.asp?id=43912070 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Завьялов Д.Е., Нечаев К.В., Зыбина O.A., Бабкин О.Э., Мнацаканов С.С. Реакции в огнезащитных вспучивающихся красках в присутствии углеродных нанотел // Лакок расочные материалы и их применение. 2012. № 10. С. 38–39. URL: https://www.elibrary.ru/item.asp?id=20274080</mixed-citation><mixed-citation xml:lang="en">Zavyalov D.E., Nechaev K.V., Zybina O.A., Babkin O.E., Mnatsakanov S.S. Reaction, which take place in the intumescent fire­retardant paints in the presence of carbon nanobodies. Russian Coatings Journal/Lakokrasochnye materialy i ikh primenenie. 2012; 10:38­39. URL: https://www.elibrary.ru/item.asp?id=20274080 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Завьялов Д.Е., Зыбина O.A., Мнацаканов С.С., Чернова Н.С., Варламов A.C. Огнезащитные вспучивающиеся композиции на основе интеркалированного графита // Химическая промышленность. 2009. Т. 86. № 8. С. 414–417.</mixed-citation><mixed-citation xml:lang="en">Zavyalov D.E., Zybina O.A., Mnatsakanov S.S., Chernova N.S., Varlamov A.S. Fire­resistant intumescent compositions containing intercalated graphite. Chemical industry. 2009; 86(8):414­417. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Gillet M., Autrique L., Perez L. Mathematical model for intumescent coatings growth: application to fire retardant systems evaluation // Journal of Physics D: Applied Physics. 2007. Vol. 40. Issue 3. Pp. 883–899. DOI: 10.1088/0022­3727/40/3/030</mixed-citation><mixed-citation xml:lang="en">Gillet M., Autrique L., Perez L. Mathematical model for intumescent coatings growth: application to fire retardant systems evaluation. Journal of Physics D: Applied Physics. 2007; 40(3):883­899. DOI: 10.1088/00223727/40/3/030</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Бабкин О.Э., Зыбина O.A., Танклевский Л.T., Мнацаканов С.С. Диагностика качества нанесения и эффективности коксообразующих огнезащитных покрытий для металлоконструкций // Промышленные покрытия. 2014. № 7–8. С. 50–54.</mixed-citation><mixed-citation xml:lang="en">Babkin O.E., Zybina O.A., Tanklevskii L.T., Mnatsakanov S.S. Diagnosis of the quality of application and effectiveness of coke­forming flame retardant coatings for metal structures. Industrial Coatings. 2014; 7­8:50­54. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Зыбина O.A., Бабкин О.Э., Танклевский Л.Т., Мнацаканов С.С. Формирование интумесцентного слоя при термолизе органофосфат аммонийных огнезащитных покрытий // Мир гальваники. 2014. № 5. С. 56–58.</mixed-citation><mixed-citation xml:lang="en">Zybina O.A., Babkin O.E., Tanklevsky L.T., Mnatsakanov S.S. Formation of the intumescent layer during thermolysis of organophosphatammonium flame retardant coatings. Galvanic World. 2014; 5:56­58. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Yuan J. Intumescent coating performance on steel structures under realistic fire conditions : Doctor of Philosophy thesis, School of Mechanical, Aerospace and Civil Engineering, University of Manchester, 2009.</mixed-citation><mixed-citation xml:lang="en">Yuan J. Intumescent coating performance on steel structures under realistic fire conditions : Doctor of Philosophy thesis, School of Mechanical, Aerospace and Civil Engineering, University of Manchester, 2009.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Dowling J. Fire protection costs for structural steelwork. New Steel Construction. UK, 2003.</mixed-citation><mixed-citation xml:lang="en">Dowling J. Fire protection costs for structural steelwork. New Steel Construction. UK, 2003.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Sorathia U., Gracik T., Ness J., Durkin A., Williams F., Hunstad M., Berry F. Evaluation of intumescent coatings for shipboard fire protection // Journal of Fire Sciences. 2003. Vol. 21. Issue 6. Pp. 423–450. DOI: 10.1177/0734904103035393</mixed-citation><mixed-citation xml:lang="en">Sorathia U., Gracik T., Ness J., Durkin A., Williams F., Hunstad M., Berry F. Evaluation of Intumescent Coatings for Shipboard Fire Protection. Journal of Fire Sciences. 2003; 21(6):423­450. DOI: 10.1177/0734904103035393</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Perez L., Autrique L., Pechoux F. Modelling and experimental testing of intumescent coatings under high thermal flux for military applications // Fire Safety Science. 2014.</mixed-citation><mixed-citation xml:lang="en">Perez L., Autrique L., Pechoux F. Modelling and experimental testing of intumescent coatings under high thermal flux for military applications. Fire Safety Science. 2014.</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Roberts T., Shirvill L., Waterton W., Buckland I. Fire resistance of passive fire protection coatings after long­term weathering // Process Safety and Environmental Protection. 2010. Vol. 88. Issue 1. Pp. 1–19. DOI: 10.1016/j.psep.2009.09.003</mixed-citation><mixed-citation xml:lang="en">Roberts T., Shirvill L., Waterton W., Buckland I. Fire resistance of passive fire protection coatings after long­term weathering. Process Safety and Environmental Protection. 2010; 881(1):1­19. DOI: 10.1016/j.psep.2009.09.003</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Kandola B.S., Akonda M.H., Horrocks A.R. Use of highperformance fibres and intumescents as char promoters in glassreinforced polyester composites // Polymer Degradation and Stability. 2005. Vol. 88. Issue 1. Pp. 123–129. DOI: 10.1016/j.polymdegradstab.2004.01.030</mixed-citation><mixed-citation xml:lang="en">Kandola B.S., Akonda M.H., Horrocks A.R. Use of high­performance fibres and intumescents as char promoters in glass­reinforced polyester composites. Polymer Degradation and Stability. 2005; 88(1):123­125. DOI: 10.1016/j.polymdegradstab.2004.01.030</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Jimenez M., Duquesne S., Bourbigot S. Characterization of the performance of an intumescent fire protective coating // Surface and Coating Technology. 2006. Vol. 201. Issue 3–4. Pp. 979–987. DOI: 10.1016/j.surfcoat.2006.01.026</mixed-citation><mixed-citation xml:lang="en">Jimenez M., Duquesne S., Bourbigot S. Characterization of the performance of an intumescent fire protective coating. Surface and Coating Technology. 2006; 201(3­4): 979­987. DOI: 10.1016/j.surfcoat.2006.01.026</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Andersen J. Experimental study of the thermal resistance of intumescent coatings exposed to different heating rates : Master of Science thesis, Civil Engineering Department, Technical University of Denmark, Copenhagen, Denmark, 2015.</mixed-citation><mixed-citation xml:lang="en">Andersen J. Experimental study of the thermal resistance of intumescent coatings exposed to different heating rates : Master of Science thesis, Civil Engineering Department, Technical University of Denmark. Copenhagen, Denmark, 2015.</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Li G.Q., Lou G.B., Zhang C., Wang L., Wang Y. Assess the fire resistance of intumescent coatings by equivalent constant thermal resistance // Fire Technology. 2012. Vol. 48. Issue 2. Pp. 529–546. DOI: 10.1007/s10694­011­0243­8</mixed-citation><mixed-citation xml:lang="en">Li G.Q., Lou G.B., Zhang C., Wang L., Wang Y. Assess the fire resistance of intumescent coatings by equivalent constant thermal resistance. Fire Technology. 2012; 48(2):529­546. DOI: 10.1007/s10694­011­0243­8</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Omrane A., Wang Y.C., Goransson U., Holmstedt G., Alden M. Intumescent coating surface temperature measurement in a cone calorimeter using laser­induced phosphorescence // Fire Safety Journal. Vol. 42. Issue 1. Pp. 68–74. DOI: 10.1016/j.firesaf.2006.08.006</mixed-citation><mixed-citation xml:lang="en">Omrane A., Wang Y.C., Goransson U., Holmstedt G., Alden M. Intumescent coating surface temperature measurement in a cone calorimeter using laser­ induced phosphorescence. Fire Safety Journal. 2006; 42(1):68­74. DOI: 10.1016/j.firesaf.2006.08.006</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Bartholomai M., Schriever R., Schartel B. Influence of external heat flux and coating thickness on the thermal insulation properties of two different intumescent coatings using cone calorimeter and numerical analysis // Journal of Fire Materials. 2003. Vol. 27. Pp. 151–162.</mixed-citation><mixed-citation xml:lang="en">Bartholomai M., Schriever R., Schartel B. Influence of external heat flux and coating thickness on the thermal insulation properties of two different intumescent coatings using cone calorimeter and numerical analysis. Journal of Fire Materials. 2003; 27:151­162.</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Zhang Y., Wang Y., Bailey C.G., Taylor A.P. Global modelling of fire protection performance of intumescent coating under different cone calorimeter heating conditions // Fire Safety Journal. 2012. Vol. 50. Pp. 51–62. DOI: 10.1016/j.firesaf.2012.02.004</mixed-citation><mixed-citation xml:lang="en">Zhang Y., Wang Y., Bailey C.G., Taylor A.P. Global model ling of fire protection performance of intumescent coating under different cone calorimeter heating conditions. Fire Safety Journal. 2012; 50:51­62. DOI: 10.1016/j.firesaf.2012.02.004</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Зыбина O.A., Варламов A.B., Чернова Н.С., Мнацаканов С.С. О роли и превращениях компон ентов огнезащитных вспучивающихся лакокрасочных композиций в процессе термолиза // Журнал прикладной химии. 2009. Вып. 82. № 4. С. 1445–1449. URL: https://www.elibrary.ru/item.asp?id=44519592</mixed-citation><mixed-citation xml:lang="en">Zybina O.A., Varlamov A.B., Chernova N.S., Mnatsakanov S.S. On the role and transformations of components of intumescent fire­retardant paintand­varnish formulations in the course of thermolysis. Russian Journal of Applied Chemistry. 2009; 82(4):1445­1449. URL: https://www.elibrary.ru/item.asp?id=44519592 (rus).</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Wang L., Dong Y., Zhang D., Zhang C. Experimental study of heat transfer in intumescent coatings exposed to non­standard furnace curves // Fire Technology. 2015. Vol. 51. Issue 3. Pp. 627–643. DOI: 10.1007/s10694­015­0460­7</mixed-citation><mixed-citation xml:lang="en">Wang L., Dong Y., Zhang D., Zhang C. Experimental study of heat transfer in intumescent coatings exposed to non-standard furnace curves. Fire Technology. 2015; 51(3):627-643. DOI: 10.1007/s10694‑015‑0460‑7</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Головина Е.В. Методика оценки термостойкости огнезащитных составов интумесцентного типа для объектов нефтегазовой отрасли : дис. … канд. техн. наук. Екатеринбург, 2019. 130 с.</mixed-citation><mixed-citation xml:lang="en">Golovina E.V. Methodology for the evaluation of thermal resistance of intumescent-type flame retardant compositions for oil and gas facilities  : Dissertation of the Candidate of Technical Sciences. Ekaterinburg, 2019; 130. (rus).</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Оценка огнезащитных свойств покрытий в зависимости от сроков их эксплуатаци : методика. М. : ВНИИПО, 2014. 31 с.</mixed-citation><mixed-citation xml:lang="en">Assessment of fire protection properties of coatings depending on the terms of their operation: a methodology. Moscow, VNIIPO, 2014; 31. (rus).</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
